Your oven comes prefitted with a mains cable.
If you need to change it:
1. Open the terminal block cover with screwdriver.
2. Pass the mains lead under the cable clamp and
secure clamp with the screw over the outer
cable insulation.
3. Connect the cables according to the supplied
diagram.
4. Close the cover of the terminal block once the
wiring is complete.
5. Mains cable must not be longer than 2 metres
for safety reasons.
6. The mains lead should be routed away from the
appliance and not be trapped between the
appliance and the wall.
Cooling fan
1- Fan
2- Control panel
3- Door
The Built-in cooling fan cools both the front of the
appliance and cabinetry.
Do not switch the oven off at the mains
isolation switch immediately after cooking.
Cooling fan continues to run for up to 20-30
minutes (approx) even after the oven control is
turned off.
3
2
1
Installation
Slide the o
Fix your oven with 4 screws and retainers.
ven into the cabinet aperture, align
and secure.
Final check
Connect the appliance to the mains supply,
switch on the mains supply and check the oven’s
functions,
www.howdens.com
Page _ 22
LAMONA
Appliances
L
N
Terminal
Live: Brown
Earth: Green /
Neutral :
Cable clamp