Lamona LAM1217 Скачать руководство пользователя страница 13

13

Instructions and Installation

Clearances and dimensions

A

  Minimum distance between 

cabinets must be equal to 

overall width of hob.

B

  Minimum height to extractor 

as recommended in extractor 

instruction manual.

C

  400mm minimum between 

worktop and cabinetry within 

170mm either side of the hob.

D

  55mm minimum between  

cut-out and vertical surface 

above the worktop.

 No shelf or overhang of 

combustible material should  

be closer than 650mm directly 

above the hob.

There must be a minimum 

clearance of 50mm between  

the rear edge of the cut-out  

and the rear wall. This clearance 

must be maintained up to  

650mm above the worktop  

(unless otherwise stated in your 

extractor manual).

The rear wall is any vertical 

surface behind the hob. If any 

tiles, backboards, splashbacks  

or upstands are fitted the distance 

is taken from the front face of 

these items.

50mm min.

560mm

50mm min.

490mm

B

A

D

C

Содержание LAM1217

Страница 1: ...www howdens com appliance registration Electric Solid Plate Hob LAM1217 Instructions and Installation...

Страница 2: ...2 www howdens com Electric Solid Plate Hob LAM1217 ai163549733715_J6395_Lamona Extended Warranty Labels_Update_V1_AW_OL pdf 1...

Страница 3: ...this user manual within easy reach for future reference Register your appliance to access a digital copy of your user manual for future reference Please read any other documents supplied with the prod...

Страница 4: ...ructions 8 Waste regulation 8 Package information 8 Future transportation 8 4 Using the hob 9 Controls 9 Hob layout 10 Over heating protection 10 5 Cleaning and maintenance 11 How to clean your hob 11...

Страница 5: ...not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction Children be...

Страница 6: ...mains supply The separation must be provided by a switch built into the fixed electrical installation according to construction regulations Any work on electrical equipment and systems should only be...

Страница 7: ...risk Ensure all electrical connections are secure and tight to prevent risk of arcing Do not use damaged cables or extension cables Ensure liquid or moisture is not accessible to the electrical conne...

Страница 8: ...event potential negative consequences for the environment and human health Compliance with RoHS Directive The product you have purchased complies with EU RoHS Directive 2011 65 EU It does not contain...

Страница 9: ...not intended to be operated by means of an external timer or separate control system 4 Using the hob Controls Rotate in either direction to switch on and select the heat level Each zone has 6 fixed he...

Страница 10: ...el on the hotplate The bottom of the saucepan or vessel is not completely flat A B E F G H I D C A Rear Left Zone Rapid 145mm 1500W Suitable for 6 or 15cm diameter saucepan B Rear Right Zone Standard...

Страница 11: ...r sponge as these can leave a film of detergent on the surface which can lead to discolouration Apply a thin coat of cooking oil from time to time to provide a protective coating Do not use steam clea...

Страница 12: ...l surfaces above the work surface and in the immediate vicinity of the cooking hob must be heat resistant Laminated surfaces and the adhesive used for fixing them must be heat resistant in order to av...

Страница 13: ...urface above the worktop No shelf or overhang of combustible material should be closer than 650mm directly above the hob There must be a minimum clearance of 50mm between the rear edge of the cut out...

Страница 14: ...brackets provided taking the thickness of the worktop into account Your appliance will be supplied and installed using the following installation method Typical fixing points Typical fixing points Met...

Страница 15: ...esult in damage to the worktop and invalidate your guarantee Apply a thin bead of the putty seal provided to the underside of the hob For best results ensure the putty is applied evenly as close to th...

Страница 16: ...eutral supplies are switched and disconnected at the same time The terminations labelled SUPPLY are connections for the internal house wiring and the terminations labelled LOAD are for connection to t...

Страница 17: ...be replaced by a suitably qualified person mains cable must not be longer than 2m for safety reasons It should be routed away from the appliance and not trapped between the appliance and the wall You...

Страница 18: ...38mm Outer dimensions Width 560mm Depth 490mm Cook zones Rear Left Zone Rapid 145mm 1500W Rear Right Zone Standard 180mm 1500W Front Left Zone Rapid 180mm 2000W Front Right Zone Rapid 145mm 1500W Sup...

Страница 19: ...product The guarantee is invalid if the product is tampered with or repaired by any unauthorised person The guarantee in no way affects your statutory or legal rights What to do if you need to report...

Страница 20: ...n le Vieil Cedex France Product information correct at the time of publication in March 2022 The company has a policy of continuous product development and reserves the right to change any products an...

Отзывы: