background image

Manual 

Wind Sensors EFFICIENT Modbus (14579)

(14579) EFFICIENT Modbus

Manual

Disposal

LAMBRECHT meteo GmbH is listed and registered at the Stiftung Elektro-Altgeräte Register ear under:

WEEE-Reg.-No. DE 45445814

In the category of monitoring and control instruments, device type: “Monitoring and control instruments for exclusively com-

mercial use”.

Within the EU

The device has to be disposed according to the European Directives 2002/96/EC and 2003/108/EC (Waste Elec-

trical and Electronic Equipment). Do not dispose the old device in the household waste! For an environmentally 

friendly recycling and disposal of your old device, contact a certified disposal company for electronic waste.

Outside the EU

Please follow the regulations in your country regarding the appropriate disposal of waste electronic equipment.

Content

Initial operation 

3

Principles of installation 

3

Setting up the North direction  

 

of the wind direction sensor 

4

Electrical connection 

4

5 Heating 

4

6 Maintenance 

4

Wiring diagram 

5

Dimensional drawings 

6

Modbus data protocols EFFICIENT Modbus 

7

9.1 General 

7

9.2 

Data encoding 

7

9.3 

Standard configuration - Default  

7

9.4 

Available Modbus commands 

7

9.5 

Instantaneous values / realtime values (Input Register) 

8

9.6 

Period data - Average, maximum and minimum (Input Register) 

8

9.7 

Descriptive sensor parameter registers (Holding Register) 

9

9.8 

Configuration registers (Holding Register) 

9

9.9 

Autoconfiguration 

9

10 

Technical data 

10

2

Содержание EFFICIENT Modbus

Страница 1: ...or concept high quality materials meet func tional design EFFICIENT sensors also impress with their high accuracy effortlessly simple mounting principles and corrosion resistant materials EFFICIENT se...

Страница 2: ...t a certified disposal company for electronic waste Outside the EU Please follow the regulations in your country regarding the appropriate disposal of waste electronic equipment Content 1 Initial oper...

Страница 3: ...the upper wind speed sensor is 0 1 to 0 5 m above the upper edge of the lower wind direction sensor 2 Principles of installation Because the installation takes place in a danger ous height the assembl...

Страница 4: ...s the North mark on the sen sor must be aligned with the geographical north direction You have to turn the marking exactly over the marking at the sensor shaft When you have aligned the marks you may...

Страница 5: ...Manual Wind Sensors EFFICIENT Modbus 14579 14579 EFFICIENT Modbus Manual 7 Wiring diagram 5...

Страница 6: ...Manual Wind Sensors EFFICIENT Modbus 14579 14579 EFFICIENT Modbus Manual 8 Dimensional drawings Accessories optional 14567 U6 Mast adapter Id No 32 14567 006 000 6 3 10 mm...

Страница 7: ...or Values of 9999 indicate an internal sensor error 9 3 Standard configuration Default Baud rate 19200 Baud Byte frame 8E1 1 start bit 8 data bits 1 parity bit even parity 1 stop bit RTU Sensor addres...

Страница 8: ...ent request and the previous request The maximum range of a period is 1 hour Recalling the average value of a minimum maximum and average group will erase the appropriate registers Retrieve the values...

Страница 9: ...egister 8 Checksum OK 8BCA LEN 19 Transmission Response Source Slave 13 Dest Master Function Read Holding Register 3 Func Desk Byte count 16 Data 30 30 2E 31 36 34 38 30 2E 30 30 31 31 33 30 00 Checks...

Страница 10: ...stics Measuring ranges 0 360 0 7 50 m s Accuracy 2 0 5 m s at 0 7 5 m s and 2 FS at 5 02 50 m s Resolution 1 0 02 m s Starting value 0 7 m s 0 7 m s Interface RS485 RS485 Protocol Modbus RTU Modbus RT...