Lambrecht ARCO-Modbus 14581 Скачать руководство пользователя страница 4

Manual 

Combined Wind Sensor ARCO-Modbus

(14581) ARCO-Modbus

Manual

2.6 

Mounting the Cup Rotor of the Wind  

 

Speed Sensor

The bores at the cup rotor are provided in such a way that the 

cup rotor can only be installed in a certain, clear position. In 

each case all screws must be used to attach the cup anemom-

eter and wind vane. Thus the correct direction of rotation is 

guaranteed. The necessary wrench is included in the delivery.

1

Schraube mit Innensechskant

screw with hexagon socket

M3x12 DIN7380

2

Windfahne / wind vane

3

Windfahnenglocke / wind vane protective globe

4

Skt-Stiftschlüssel / hex head wrench

4

1

2

3

2.7 

Installation Procedure (Brief Explanation)

The installation of the sensor involves 3 steps:
(1) Mounting the cable on the sensor and if necessary drawing 

the cable through the mast.

(2) Mounting the sensor on the mast, but before tightening the 

screws you must align the sensor to the north.

(3) Attaching the cable to the power supply and the signal 

acquisition system.

2.8 

Mounting the Sensor

The sensor can be installed on a standard pipe with an outer 

diameter of 50 mm and an inner diameter of at least 40 mm.
Before attaching the unit with the two 8 mm socket screws, 

the cable must be connected, by drawing it through the pipe 

and the sensor aligned to the north or in the forward driving  

direction. For this purpose the housing is marked accordingly 

(see drawing). Adjust the sensor to the north before tightening 

the screws. 
Please make sure that the sensor is firmly attached to the 

mast!

2.8.1  Alignment of Wind Vane

For wind direction measurements the north mark on the 

sensor must be aligned with the geographical north direction. 

To adjust the wind sensor in a firm and correct manner into 

the north direction this item is equipped with an integrated 

mounting aid. Inside the inner bottom of the sensor a small bolt 

pointing to the north is integrated to be set into a correspond-

ing slot of the mounting pipe (if available). Thus the sensor is 

safely attached. If needed you can screw or unscrew the pin 

by means of an Allen key.
You have to turn the marking on the wind vane so that it is 

exactly over the marking on the sensor shaft. Fix the position 

of the wind vane with, for example, a piece of adhesive tape. 

After alignment the adhesive tape has to be removed.
When you have fixed the wind vane you can locate the refer-

ence point by aiming at it over the axis. Now you must turn the 

sensor casing on the mounting tube until the tip of the wind 

vane points to the reference point in the north.
To set up the sensor’s north orientation select a landmark 

which is as far as possible up north with regard to the final 

position of the wind direction sensor.

1

Halbrundschraube mit Innensechskant

round head screw with hexagon socket

M3x8 DIN7380

2

Schalenstern / cup rotor

3

Schalensternglocke / cup rotor protective globe

4

Skt-Stiftschlüssel / hex head wrench

4

1

2

3

The reference point can be selected using a topographical 

map (1:25000). The exact position of the reference point is 

determined using an amplitude compass that can be adjusted 

horizontally on a stand.

The compass declination has to be considered!  

A functional check at three points offset by 90° directions is 

recommended.

Follow all safety instructions while setting up the 

sensor on to a mast.

4

Содержание ARCO-Modbus 14581

Страница 1: ...g value of 0 3 m s Very large measuring range from 0 3 to 75 m s Quick and easy installation by pipe mounting and M12 plug connector Integrated regulated heater for optimal heating of the sensor heads...

Страница 2: ...uipment Content 1 Introduction 3 2 Start Up 3 2 1 Installation Conditions 3 2 2 Tools and Installation Aids 3 2 3 Unpacking the Sensor 3 2 4 Goods Inspection 3 2 5 Power Supply 3 2 6 Mounting the Cup...

Страница 3: ...luminum alloys The housing the cup rotor and the wind vane are anodized An electronically controlled sensor heating device allows for operation of the sensor over the wide range of 30 70 C 2 Start Up...

Страница 4: ...d direction measurements the north mark on the sensor must be aligned with the geographical north direction To adjust the wind sensor in a firm and correct manner into the north direction this item is...

Страница 5: ...cuitbreaker must be switched off It is not permitted for unauthorized persons to open the housing 3 Maintenance 3 1 Regular Maintenance and Calibration The sensors are very low maintenance and designe...

Страница 6: ...Manual Combined Wind Sensor ARCO Modbus 14581 ARCO Modbus Manual 5 Dimensional Drawing and Electrical Connection ARCO Modbus 6...

Страница 7: ...Manual Combined Wind Sensor ARCO Modbus 14581 ARCO Modbus Manual Electrical connection ARCO Modbus 7...

Страница 8: ...e by the divisor Values of 9999 indicate an internal sensor error 6 3 Standard Configuration Default Baud rate 19200 Baud Byte frame 8E1 1 start bit 8 data bits 1 parity bit even parity 1 stop bit RTU...

Страница 9: ...ss type 30002 Wind speed average m s 10 1 Read only 30003 Wind speed maximum m s 10 1 Read only 30004 Wind speed minimum m s 10 1 Read only 30202 Wind direction average 10 1 Read only 30203 Wind direc...

Страница 10: ...d Input Register 4 Func Desk Byte count 2 Data 00 14 Checksum OK 3FB9 6 7 Descriptive Sensor Parameter Registers Holding Register Register Parameter name Quantity of registers Remark Access type 40050...

Страница 11: ...01 06 48 05 10 9C 41 00 01 7E 09 LEN 9 Transmission Query Source Master Dest Slave 5 Function Write Multiple Register 16 Func Desk Address 40001 Quantity 1 Byte count 2 Register values 00 01 Checksum...

Страница 12: ...ely Sensor cable 15 m 4 pole M12 plug Id No 32 14567 060010 various lengths possible Options 9340 Visualisation and evaluation software MeteoWare CS Basic Id No 36 09340 000000 Standards EMC EMI EN 60...