40
FUME EVACUATION/AIR INTAKE
1 Concentric fl ue pipe, from the roof C32
2 Concentric fl ue pipe, from the terrace C32
3 Double fl ue pipe from separate fl ues C42
4 Concentric fl ue pipe, connected to concentric fl ues C42
5 Concentric fl ue pipe, from an external wall C12
6 Double fl ue pipe from the terrace C52
7 Double fl ue pipe from single fl ue C82
8 Double fl ue pipe C62
For positioning and for distances of draught terminals from windows, doors, etc. see regulations in force.
4
3
3
2
1
5
4
6
7
8
5
6
CONNECTION TO THE CHIMNEY - VERSION XILO T 20 N MS W TOP
The boiler is for combustion in a sealed chamber and does not require any special ventilation, it can also be
located in small rooms, lumber-rooms, laboratories. In addition, there are various possibilities for combustion fume
evacuation and external air intake; basically the boiler is designed for two types of fume evacuation/air intake:
●
fume evacuation/air intake concentric pipes system,
●
fume evacuation/air intake double pipes system.
In this way it is possible, by using suitable kits, to connect the boiler to concentric fl ues, ventilating fl ues,
separate fl ues, etc. Some possible solutions are indicated below.
FLUE EXHAUST CONNECTION