-  If more than few attempts for ignition appear unsuccessful, for example if the fuel ends (parameter C1, set at two attemp-

ts), then the device turns off the normal algorithm and a mode ALARM will start – a lamp ALARM will light constantly 

which is a signal for the user that the reason should be removed. 

  After removing the disturbance in the normal work, the burner starts again with its turning off and on. 

  This may be done by the switcher POWER placed on the burner’s cover (it stops the feeding for the logical module into 

the burner and clears the alarm) or by turning off the common boiler feeding through its main circuitbreaker;

-  When the electrical supply stops and then restores, the burner starts automatic. 

TURNING THE BURNER OFF

IMPORTANT!  

If during work you wish to turn off the burner, this must be done in the following way: 

first decrease the set temperature 

from the boiler thermostat through its turning in starting position.

After 5 minutes (time enough for the combustion of the pellets in the burner), the burner turns off through its switch and 

the boiler respectively through its main switch. 

ATTENTION

 

if the above sequence is not kept, the pellets burn out without burner fan turned on (it is possible overheating and break-

down of the photosensor).

Содержание GP 20

Страница 1: ...BRUCIATORE A PELLET PELLET BURNER BR LEUR PELLETS GP 20 LIBRETTO DI INSTALLAZIONE E MANUTENZIONE INSTALLATION AND MAINTENANCE MANUAL NOTICE D INSTALLATION ET D ENTRETIEN...

Страница 2: ...ty installation use and maintenance of the burner Keep the manual in a safe place for future consultation Installation must be carried out by qualified personnel in conformance with technical standard...

Страница 3: ...ATION 36 USe and MAIntenance MAINTENANCE Page 38 BURNER MAINTENANCE 40 POSSIBLE TROUBLESHOOTING 41 Complimenti on your excellent choice And thank you for choosing our products LAMBORGHINI CALORECLIMA...

Страница 4: ...et Tracking the burning process photo heating and positioning sensors Light signalization for the burner performance Controlling microprocessor Ignition automatic Possibility for adjusting the outgoin...

Страница 5: ...R switch placed on the burner s cover it stoppes the feeding of the logistical module in the burner and clears the alarm or by stopping the common feeding of the boiler through its main switch The pro...

Страница 6: ...GENERAL 28 DESCRIPTION OF THE CONSTRUCTION 40 2 4 220 165 251 34 178 272 5 1 1 Burner 2 Auger transporter 3 Flexible tube...

Страница 7: ...ter Flexible tube Body feeding chute and cover Fan Ignite heater Control block Sensors exclusion mechanism photosensor thermoswitch The burner contains mainly of the following composition parts Body w...

Страница 8: ...PTION CODE 1 Auger s engine GP 20 A CODE 001 2 Auger spring GP 20 A CODE 002 3 Auger s tube GP 20 A CODE 005 4 Fan GP 20 CODE 008 5 Logical module GP 20 CODE 009 6 Feeding module GP 20 CODE 009BPS 7 I...

Страница 9: ...ENGLISH GENERAL 31 POSITION OF THE ELEMENTS...

Страница 10: ...GENERAL 32...

Страница 11: ...ENGLISH GENERAL 33...

Страница 12: ...scheme ATTENTION The connection must be done by a qualified electrical technician and there must be paid high attention to the safety grounding of the device The connecting is shown in the present man...

Страница 13: ...iler ALARM Thermostat Brown Black Power 220 V Neutral conduct Blue Yellow green First feeding of the auger Start burner signal for logic module Photosensor Photocell flame detector Feeding and fitting...

Страница 14: ...stat must be set at 80 90 C In this case the burner is fed with pressure the POWER light is on there is a signal from the boiler to the burner to start the RUN light is on and the burner starts for ex...

Страница 15: ...nto the burner and clears the alarm or by turning off the common boiler feeding through its main circuitbreaker When the electrical supply stops and then restores the burner starts automatic TURNING T...

Страница 16: ...tempts for new ignition end The number of the ignition attempts is n 1 where n is the setting of counter C1 If at n 1 attempts the ignition is not reached at the n attempt in this case the third attem...

Страница 17: ...decrease the pellets feeding If the temperature is too low increase the quantity of the air supply if the pellets level in the burner is too low check the flue gases temperature see above and decreas...

Страница 18: ...f pellets quality Before starting the burner cleaning it must be stopped by the above way turn the thermostat down and leave the burner working for 4 8 minutes more turn off the boiler s main switch a...

Страница 19: ...rheating on the burner s feeding tube not pressed exclusion mechanism controlling the reliable burner s fixture to the boiler unsuccessful ignition if there is not enough initial dose of pellets or a...

Страница 20: ...INI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene pi opportuno per l evoluzione del prodotto The illustrations and data given are indicative and are not...

Отзывы: