ENGLISH
INSTALLATION
-
-
- If more than few attempts for ignition appear unsuccessful, for example if the fuel ends (parameter C1, set at two attemp-
ts), then the device turns off the normal algorithm and a mode ALARM will start – a lamp ALARM will light constantly
which is a signal for the user that the reason should be removed.
After removing the disturbance in the normal work, the burner starts again with its turning off and on.
This may be done by the switcher POWER placed on the burner’s cover (it stops the feeding for the logical module into
the burner and clears the alarm) or by turning off the common boiler feeding through its main circuitbreaker;
- When the electrical supply stops and then restores, the burner starts automatic.
TURNING THE BURNER OFF
IMPORTANT!
If during work you wish to turn off the burner, this must be done in the following way:
first decrease the set temperature
from the boiler thermostat through its turning in starting position.
After 5 minutes (time enough for the combustion of the pellets in the burner), the burner turns off through its switch and
the boiler respectively through its main switch.
ATTENTION
•
if the above sequence is not kept, the pellets burn out without burner fan turned on (it is possible overheating and break-
down of the photosensor).