Vega 900 Handbook 

                                                                                         �

                                                                   Part Number 17155

Modules

Note Output Range

Current

Slots

Turns

Max. Current 

Limit

Settings for hazard-

ous energy

Standard Modules

H5/3

16.2-28V

5A

1

5

7.5A

>32V

9.1-15.5

6A

3

7.5A

-

H5/4

16.2-28V

5A

1

5

7.5A

>32V

16.3-24V

4.5A

4

6A

-

Seriesed Modules

BB4

32.6-40V

10A

2

8

12.5A

>19.2V

CC3

18.2-30V

18A

2

6

22.5A

>10.6

CC5

48.1-60V

10A

2

10

12.5A

>19.2V

DD4

28-36V

18A

3

8

22.5A

>10.6V

DD5

42-56V

15A

3

10

18.75A

>12.8V

EE2

7.6-15V

55A

4

4

75A

>3.2V

EE4

28-38V

30A

4

8

37.5

>6.4

EE5L

40-48V

18A

4

10

33.8

>7.1

EE5H

48-56V

18A

4

10

31.3

>7.6

HH5/3

25.3-38V

5A

1

8

7.5A

>32V

HH5/4

32.5-46V

4.5A

1

9

6A

>40V

C5B4

43-48V

10A

2

9

12.5A

>19.2V

Paralleled Modules

Z2(D1L+D1L)

1.8-3.4V

95A

3

1+1

125A

>1.9V

Z3(E1+E1)

1.8-3.4V

114A

4

1+1

150A

>1.6V

Z4(D1H+D1H)

3.9-5.1V

95A

3

1+1

125A

>1.9V

Z6(E2+D1H)

3.9-5.1V

104.5A

3.5

2+1

137.5A

>1.7V

Z7(D3+D3)

8-15V

45.6A

3

3+3

60A

>4V

Z18(L1+L1)

4.2-5.1V

66.5A

2

1+1

87.5A

>2.7V

Z19 (E5H+D5)

24-28V

36

3.5

5+5

40.05A

>5.9

Wide Range Modules

W5

5

0.25-32V

8.5A

1

5

9.5A

18>25.2V

1   

C1Y module is only permitted in slot.    

2  

 For PSUs with three D modules fitted or two D modules and an E module in slots  

 

4/5 then D1L &

 D1H in slots 2/3 is limited to 42A and in slots 4/5 is limited to 47A.   

 

D2 in slots 2/3 is limited to 40A. 

3  

 E2 module fitted in slots 4/5 is limited to 55A. 

4  

SELV and Outputs connected in Series 

 

Outputs are SELV except as described below 

 

- Non-earthed outputs that have secondaries with 2 or more turns are non-SELV as  

 

a single fault in the secondary may make them exceed the SELV limit between  

 

output and earth. 

 

- Non-earthed ouputs that are connected in series are non-SELV unless all the  

 

seriesed outputs use 1 turn secondaries and there are no more than 3 outputs  

 

connected in series. 

 

- Outputs connected in series are non-SELV if the total output v 20% of the  

 

max, rated output voltage of the output with the highest rated voltage exceeds  

 

60dc (the 20% addition allows for a single fault in any one individual channel) 

 

- The total voltage of a seriesed output must not exceed 160V 

 

- If any ouput or seriesed output is non-SELV then all the outputs in the PSU must  

 

be considered non-SELV 

 

Note 

 

- Non-SELV outputs must be gaurded or a deflector fitted during installation to  

 

avoid a service  

 

engineer making inadvertent contact with the output terminals, or dropping a tool  

 

onto them. 

 

- All outputs operational spacings to earth, and due consideration must be given to  

 

this in the end product design. 

5     

W5 is followed by V or R indicating Voltage or Resistance programming, both  

 

followed by # 

   6   

Actual voltage and current output of an X module is dependent, and limited by, the    

 

          ratings of the modules from which it is fed. The ratings given above for the X module   

 

 

are additional rating li

mitations imposed by the X module itself.   

  7   

The maximum power output of psu’s fitted with X modules is reduced from 900W b

y the  

 

 

following power: 

          

Power=0.55 x (Total X1 current) + 0.7 x (Total X2 + X4 current) + 0.9 x (Total X8 cur-

Module Limitations- Notes:

Safety approvals

UL60950-1 and CSA22.2 No.60950-1 -  UL Recognised. C-UL for Canada.  

 IEC/EN60950-1  -  BSI Kitemark and CE mark. 

CE marking when applied to any Vega product, indicates compliance with the Low Voltage Directive 

(73/23EEC) as modified by the CE Marking Directive  

(93/68/EEC) in that it complies with EN60950-1.

 

IEC/EN61010-1 and IEC/EN60601-1.  CB Report .and BSI Kitemark 

UL60601-1 and UL61010-1-UL Recognised, C-UL for Canada.

8.   

Adjusting output voltage beyond the stated range may cause overvoltage protection  

 

(OVP) to operate, whereby all outputs will turn off. To reset OVP, turn back output  

 

voltage adjustment and remove the mains supply for 30 seconds and then will switch  

 

back on.

Approval Limitations:  Use in North America (AC units only)

When this product is used on 180VAC-250VAC mains with no neutral, connect the two live wires 

to L(live) and N (neutral) terminals on the input connector.  In this instance double pole fusing is 

required.

High Voltage Warning

Dangerous voltages present within the power supply.  Do not remove covers. 

External Hot Surfaces

Section 6 of the Health and Safety at Work Act requires that manufacturers have an obligation to 

protect service engineers as well as users.  In order to comply with this, a label must be fitted to 

these products which is clearly visible to service personnel accessing the overall equipment, and 

which legibly warns that surfaces of these products may be hot and must not be touched when the 

products are in operation. 

Safety Earthing Screw

On products with an enclosure, special safety earthing screws are used  which connect the cover to 

the chassis. They must not be removed. 

Safety Class of Protection

These products are designed for the following parameters : Material Group IIIb, Pollution Degree 2, 

Overvoltage Category II, Class 1 (earthed), Indoor use as part of an overall  equipment such that 

the product is accessible to service engineers only.   

Energy Hazards

Certain modules are capable of providing hazardous energy (240VA) according to output voltage 

setting.  Final equipment manufacturers must provide protection to service personnel against 

inadvertent contact with these module output terminals.  If set such that hazardous energy can 

occur then the module terminals or connections must not be user accessible.

Servicing

These products are not customer serviceable.  Repairs may only be carried out by Lambda UK or 

 their authorised agents. These products are not authorised for use as critical components in nuclear  

control systems, life support systems or equipment for use in hazardous environments without the  

express written approval of the Managing Director of Coutant Lambda Ltd.  

Important safety instructions

The Vega family of component power supplies is designed for use within other equipment or 

enclosures which restrict access to authorised competent personnel only.  For safe installation and 

operation of this product, carefully follow the instructions listed below. 

i)   The unit covers/chassis are designed to protect only skilled personnel from hazards and must 

not be made user accessible. 

ii) These products are Class 1 and must therefore be reliably earthed and professionally installed 

in accordance with the prevailing electrical wiring regulations and the safety standards covered 

herein. 

iii)  These products are IPX0, and therefore chemicals/solvents, cleaning agents and other liquids 

must not be used.   

iv)  If the earth terminal of the Vega PSU is connected to the main incoming earth conductor of 

the end equipment, the installer must cover the Vega earth symbol with a label bearing the earth 

symbol of IEC60417-5019.

General installation instructions

Emissions :

  EN55022 Conducted RFI-Class A or B (depending on product - Consult Technical 

Sales).  Radiated RFI - Class A 

EN61000-3-2 / A14  -  Pass - Class A and D.  EN61000-3-3 / A1     - Pass  

Immunity:

  EN61000-4-2 - Level 4 Criteria B  EN61000-4-3 - Level 3 Criteria B 

EN61000-4-4 - Level 4 Criteria B  EN61000-4-5 - Level 4 Criteria B, (Installation Class 4, Criteria B) 

EN61000-4-6 - Level 3 Criteria B  EN61000-4-11 - Pass

EMC performance

Dielectric Strength testing is carried out as follows 

Primary mains circuit to earth - 2.25 - 2.35kVDC 

Primary mains circuits to transformer core - 4.25 - 4.35kVDC* 

Primary mains circuits to secondary -4.25 - 4.35kVDC* 

Outputs to each other and to earth are isolated to 200VDC. 

*This test is not possible with modules fitted to the unit as damage to RFI capacitors will occur)

Environmental parameters

Operation 

Temperature 0 to 50

0

C (derating 2.5%

0

C above 50

0

C to 65

0

C - Not covered by approvals). 

Humidity 5 to 95% RH non-condensing.  Air Pressure 78kPa to 106kPa. 

Altitude -200m to 3000m.  

Storage and Transportation 

Temperature -25

0

C to +85

0

C.  Humidity 5% to 95% RH non-condensing.   

Air Pressure 54kPa to 106k

Pa.  Altitude -200m to 5000m. 

Vibration and shock 

10-200Hz @ 1.5G sinewave, 20G for 15 minutes in 3 axes random vibration / 3000 bumps, 10G 

(16mS) half sinewave. 

Cooling 

Provided that the fan air intake and air outlet slots are not impeded, these units may be mounted 

in any of 4 orientations: Horizontal, on either side, or vertical with airflow upwards.  For correct 

airflow, allow 50mm clearance around the side and ends of the product.  

Level of insulation

Input markings and symbols

Terminal Block

Fast-ons

N

L

L

N

 alternating current (a.c.)
 direct current (d.c.)

danger, shock hazard

caution, refer to supplementary documents.

Earth

L

Live

N

Neutral

 Custom Model

Model: NS-THE/V9FSSF B/S 28E5HS  (K90036)

Input:  90-264Vac, 47-63Hz