Lambda UF1500 Series Скачать руководство пользователя страница 9

REV C

Page 9 of 17

OUTPUT VOLTAGE ADJUSTMENT (TRIMMING)

Voltage adjust potentiometers are provided for all outputs. The potentiometers are located
adjacent to the output connections of the power supply. Use a non-conductive trim-pot
adjustment tool. Turn clockwise to increase the voltage. 
NOTE:  Always monitor the corresponding output voltage while turning the potentiometer.

CURRENT LIMIT PROTECTION

All outputs are protected by constant-current limiting circuitry.  The overcurrent limits are set at
the factory between 110-150% for single outputs. The overcurrent limit settings for the dual
output modules are as follows: Output #1: 110- 150% of rated load; Output #2: 110-150% of
rated load.  Removing the overload automatically restores the output voltage.  On Dual Output
Modules - if Output #1 is in current limit, Output #2 voltage will also decrease.

OVERVOLTAGE PROTECTION (OVP)

When any single output module voltage reaches 120-130% of nominal voltage, that channel
will shut down.  When any dual output module reaches 120-140% of nominal voltage, both
outputs of the dual module will shut down.  OVP on 2V outputs is factory set to 3-3.5V, and
OVP on 3.3V outputs is set to 4.3-4.8V. OVP activates the internal shutdown latch of the
module until the AC input power is recycled OFF to ON to clear the latch and resume normal
operation, once the OVP problem has been corrected.

OUTPUT LOAD REGULATION

(NO LOAD/FULL LOAD/NO LOAD)

Single output modules 0.4% maximum.
Dual output modules 0.8% maximum.

OUTPUT LINE REGULATION

(85-265VAC 47-63 Hertz)

Single output modules 0.1% maximum.
Dual output modules 0.2% maximum.

HOLD UP TIME AFTER POWER LOSS
(AC INPUT)

The UltraFlex output voltages will remain within specified regulation for a minimum of 16msec
after loss of applied power on the AC input at full load and nominal output voltage.

TURN-OFF/TURN-ON

Turn-off/turn-on output voltage - transient overshoot is less than 3% of nominal voltage during
the application or removal of input voltage under any condition of turn-on, turn-off, including
inhibit or enable.

TURN ON TIME

All outputs shall be within voltage regulation limits within 1 second of application of AC power.

NOISE AND RIPPLE

UltraFlex output modules meet the following specifications with a 20MHz bandwidth. Care
must be taken when conducting the following measurements: 
Single output modules: 

2-5V, <1000W: <50mV pk –pk.
</= 5V, 1000W: <200mV pk-pk directly on the output terminals; 

<50mV pk-pk measured 5 inches away from the output

terminals                                                with two – 2700 uf capacitors located at this point.

 

> 5V: <1% pk–pk.

Содержание UF1500 Series

Страница 1: ...INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY UF1500 Series 3055 Del Sol Blvd San Diego CA 92154 Phone 619 575 4400 Fax 619 429 1011 P N IMUE1500 Rev C DATE February 2002...

Страница 2: ...NS 5 INPUT FUSE 6 RECEIPT AND UNPACKING 6 MOUNTING REQUIREMENTS AND COOLING 7 INPUT POWER CONNECTIONS 7 AC INPUT AND OUTPUT POWER RATINGS 7 EMI 8 INPUT TRANSIENT ESD PROTECTION 8 REMOTE SENSE 8 OUTPUT...

Страница 3: ...TURE SHUTDOWN 10 OPERATING ENVIRONMENT 10 SIZE AND WEIGHT 10 COOLING 11 SHOCK VIBRATION 11 PACKAGE DROP 11 RELIABILITY PREDICTION 11 MATING SIGNAL CONTROL CONNECTOR INFORMATION 11 GLOBAL SIGNALS 11 OU...

Страница 4: ...UF1500 Series power supply Manual part no IMUE1500 PART NUMBER CONFIGURATION U E Z 1 _ _ _ _ _ _ _ UltraFlex Case Code Global Signals Output Module Codes SEE PAGE 14 EN55022 Level B FCC20780 Class A...

Страница 5: ...ts in the product case are designed for ventilation and must not be obstructed when the product is installed and or operated G Make sure the unit is supplied only by a power source of the type indicat...

Страница 6: ...quirements this terminal must be marked with as defined in IEC417 No 5019a The customer should therefore affix an adhesive label which will pass the 15 second rub test IEC950 section 1 7 15 showing th...

Страница 7: ...takes and exhaust slots must not be obstructed The intake air temperature should be limited to allow the unit to operate in accordance with the thermal derating envelope of the electrical specificatio...

Страница 8: ...supply to the sense points To meet specifications and output voltage set point of the output modules the sense lines must be connected to the load or locally to the power supply output terminals The r...

Страница 9: ...4 8V OVP activates the internal shutdown latch of the module until the AC input power is recycled OFF to ON to clear the latch and resume normal operation once the OVP problem has been corrected OUTPU...

Страница 10: ...less than 02 per o C over the ambient temperature range of 0 50 o C After 30 minute warm up NO LOAD OPERATION Operation at no load will not cause damage to the UltraFlex supply however the output volt...

Страница 11: ...J2 Dual Output Connector Kit 951492 TO ORDER CONNECTORS DIRECT FROM AMP Single Output Input Connector AMP P N 87977 3 holds 10 Pins Dual Output Connector AMP P N 87977 1 holds 6 Pins Pin For Above Co...

Страница 12: ...dual output module Compensates for load cable drop from power supply to sense point 25V per terminal To meet regulation the remote sense must be connected to the load or locally to the power supply R...

Страница 13: ...nal causes the current share node to disconnect Maximum ratings for the output transistor are 20V 4mA Current Monitor J1 pin 9 This is an analog signal proportional to the output current 0 2VDC 2VDC a...

Страница 14: ...6W 2 P 24 V 21 6 26 4 8 5A 204W 1 Q 24 V 21 6 26 4 15A 396W 2 R 24 V 21 6 26 4 25A 600W 3 S 48 V 43 2 52 8 4A 211W 1 T 48 V 43 2 52 8 8A 384W 2 U 48 V 43 2 52 8 12 5 600W 3 V 12 5 V 10 8 13 2 4 5 6 0...

Страница 15: ...to output voltage setting Therefore consideration should be given to electrical energy hazards from these outputs THERMAL DERATING GUIDELINE for UltraFlex UF1500 Power Supply Series Derating UF1500 Se...

Страница 16: ...REV C Page 16 of 17 OUTLINE DRAWING...

Страница 17: ...REV C Page 17 of 17 LABEL CONNECTION DIAGRAM...

Отзывы: