background image

 

CONTROLS, INDICATORS, CONNECTORS 

5-8

 

5.7.1  OFF Position 

With the KEY LOCK in the OFF position, the POWER switch may be turned but HV can-

not be turned on. The unit may be locked in the OFF position and the key removed to 

protect  equipment  and  personnel.  In  normal  lab  operation,  the  KEY  LOCK CONTROL 

switch  should  remain  in  the  OFF  position  and  should  be  turned  to  LOCAL  after  the 

POWER switch is turned on and the power supply has completed its self checks. It is 

recommended that the unit always be locked in the OFF position and the KEY removed 

when not in use as a safety precaution. The key can only be removed when in the OFF 

position. It cannot be removed in either LOCAL or REMOTE positions. 

5.7.2  LOCAL Position 

With the KEY LOCK in the LOCAL position the power supply is controlled from the front 

panel (refer to section 6.1). The local voltage control, HV ON, HV OFF, and TRIGGER 

push buttons are active in LOCAL. Note that the key cannot be removed in this position. 

5.7.3  REMOTE Position 

With the KEY LOCK in the REMOTE position the front panel HV LEVEL ADJUST and 

HV ON push button are not active. These commands must be provided via the remote 

25 pin D-sub connector on the rear panel. The HV OFF push button remains active with 

the KEY LOCK in the remote position. Note that the key cannot be removed in this posi-

tion. 

5.7.4  REMOTE/LOCAL/ENABLE LEDs 

There are three LEDs adjacent to the keylock control, REMOTE, LOCAL, and ENABLE. 

The REMOTE LED indicates the keylock is in the remote position and the local controls 

have no function (except HV OFF which will override remote control). The LOCAL LED 

indicates  the  keylock  is  in  the  local  position,  and  only  the  front  panel  controls  can  be 

used to operate the supply. 
The ENABLE LED indicates that a remote enable command is being sent to the power 

supply  via  the  remote  interface.  This  is  an  important  check  turning  the  KEY  LOCK 

CONTROL switch to the REMOTE position. The presence of an ENABLE signal when 

selecting  REMOTE  mode  does  not  allow  high  voltage  to  be  generated.    The  remote 

ENABLE signal must be recycled (ON-OFF-ON) before H.V. can be generated. 
The  ENABLE  LED  will  illuminate  when  the  power  supply  KEY  LOCK  is  in  the  OFF  or 

LOCAL position as a useful indication that the remote interface is connected and opera-

tional. 

5.8 

HV OFF/Reset (Ref 7) 

The HV OFF push-button turns OFF the HV output when depressed.  This push-button 

will illuminate and stay illuminated when depressed (HIGH VOLTAGE is OFF).  The HV 

OFF push-button will always operate even with the KEY LOCK in the remote position. 
The HV OFF push-button switch will FLASH continuously when the HV output has been 

turned  OFF  automatically  by  a  latching  fault.  Latching  faults  include  INTERLOCK 

OPEN, HIGH  AC input, and IMBALANCE.  These faults may be reset by depressing the 

flashing  HV  OFF  push-button  after  the  fault  condition  has  been  cleared,  INTERLOCK 

closed, etc.  

Содержание 303 Series

Страница 1: ...9 009 Rev A OPERATOR MANUAL FOR 303 Series High Voltage POWER SUPPLY Document 83 489 009 Rev A LAMBDA AMERICAS 405 Essex Road Neptune NJ 07753 Tel 732 922 9300 Fax 732 922 9334 Web www us tdk lambda c...

Страница 2: ......

Страница 3: ...9 Power Factor 2 6 2 10 Efficiency 2 6 2 11 AC Line Filtering 2 6 2 12 Inrush Current 2 6 2 13 Max Discharge 2 6 2 14 Physical Specifications 2 6 2 15 Cooling Water 2 6 2 16 Water Fittings 2 7 2 17 We...

Страница 4: ...ormally OFF 5 5 5 2 4 2 HIGH Normally OFF 5 5 5 2 4 3 IMBALANCE Normally OFF 5 5 5 2 4 4 LOW Normally OFF 5 6 5 2 4 5 INTERLOCK OPEN Normally OFF 5 6 5 2 5 INDICATOR TROUBLESHOOTING 5 6 5 3 LOCAL VOLT...

Страница 5: ...LOAD CIRCUIT CONNECTION 4 15 FIGURE 4 1 203 303L FRONT PANEL CONTROLS AND INDICATORS 5 1 FIGURE 4 2 203 303S FRONT PANEL CONTROLS AND INDICATORS 5 10 FIGURE 4 3 203 303L REAR PANEL CONNECTIONS 5 11 FI...

Страница 6: ......

Страница 7: ...S Models have been designed to operate as a slave unit to the L Models or in systems where local control is not a requirement As many 203 or 303 supplies as required can be connected in parallel to pr...

Страница 8: ...trol connector regardless which front panel option L or S is selected The S models feature only front panel status indicators and remote controls and are a cost effective solution for applications whe...

Страница 9: ...ME between removing the AC input line and opening the cover ALSO ALLOW AT LEAST 40 SECONDS between switching the AC power off and switching it on again 1 Ensure all covers are in place and securely fa...

Страница 10: ...rtment at Lambda Americas Special options are typically shown as a four digit suffix to the model number 203 303 model voltage polarity mode input options Model L or S Output Voltage Range kV POS or N...

Страница 11: ...ot Available 180 264 VAC 50 60 Hz 3 Continuous DC 20kW Not Available 2 2 Polarity Fixed positive or negative specify when ordering 2 3 H V Return Ground through H V output cable shield to chassis and...

Страница 12: ...l current 2A or less 2 9 Power Factor 0 9 at full load and nominal AC line 2 10 Efficiency 85 at full load and nominal AC line 2 11 AC Line Filtering Passive power factor correction and EMI filters in...

Страница 13: ...tory packing 2 0 g 2 19 Shipping Gross weight with packing material 240 lbs 109 kg approx Size 27 W X 21 H X 30 D 686 mm X 535 mm X 762 mm 2 20 Air Temperature Range Operating 0 C to 55 C ambient air...

Страница 14: ...SPECIFICATIONS 2 8 NOTES...

Страница 15: ...ut cable to its return shield braid This dead short will allow the unit to generate full output current at zero voltage 1 Set the output voltage control to zero Connect the AC power to the unit Turn O...

Страница 16: ...the factory opening the supply or the assembly will void the factory warranty and may compromise performance 3 3 CONTACTING LAMBDA AMERICAS CUSTOMER SERVICE When contacting customer service locate the...

Страница 17: ...d protect the supply from environ mental contamination Never install the 203 or 303 so only the front panel screws support its weight The 203 303 must never be installed without support in the back or...

Страница 18: ...f 55 C 4 3 WATER COOLING REQUIREMENTS Water with a flow rate at 2 US gallons per minute 7 6litres min having an exit tempera ture of 15 to 35 C is required to cool the instrument This is required to m...

Страница 19: ...ic shock The metal chassis of the power supply is grounded through the earth wire at the input AC power terminal block Use ex treme caution when connecting input AC power and never apply the incorrect...

Страница 20: ...er handle the HV cable while the supply is operating Never operate the supply without a load capacitor connected Always use the HV connector and cable provided with the power supply or an equivalent s...

Страница 21: ...ket shield and any semiconducting layer that remains on the cable insulation after removing the shield The cable outer jacket should be removed to reveal the cable shield At least 12 or 300mm of outer...

Страница 22: ...INSTALLATION 4 16 NOTES...

Страница 23: ...EDs along with local remote mode keyswitch and power on switch The 203 303L can be operated locally from the front panel or remotely via the control connector located on the rear panel see Section 6 2...

Страница 24: ...tes that the power supply is ready to gen erate high voltage This indicator illuminates at the end of the automatic internal self check cycle after the POWER switch has been turned on The READY indica...

Страница 25: ...t is closed The 4 position barrier strip interlock terminals located on the rear panel see Figure 4 2 must be shorted to allow the supply to operate These terminals may be run through any number of co...

Страница 26: ...N push button when the overvolt age condition is no longer present 5 2 2 4 ARC Normally OFF When illuminated the ARC indicator signals a major fault internal to the high voltage tank of the power supp...

Страница 27: ...ormally during the auto matic purge operation The purge pump is designed to remove excess air that may ac cumulate in the high voltage tank The purge pump removes accumulated air to allow the most eff...

Страница 28: ...ower supply troubleshooting Table 5 2 shows a detailed status chart of all front panel LEDs and indicators NORMAL INDICATION TYPE OF INDICATION RESET BY ASSOCIATED INDICATORS WILL CAUSE SYSTEM NOT REA...

Страница 29: ...rent flowing in the HV output cable 5 6 TRIGGER push button Ref 5 The TRIGGER indicator push button will illuminate when an INHIBIT signal is applied to the power supply The TRIGGER indicator will ill...

Страница 30: ...LOCAL ENABLE LEDs There are three LEDs adjacent to the keylock control REMOTE LOCAL and ENABLE The REMOTE LED indicates the keylock is in the remote position and the local controls have no function e...

Страница 31: ...he POWER switch only controls a low voltage signal and is not directly connected to the main AC line This low voltage control signal is wired in series with two terminals on the rear panel 4 position...

Страница 32: ...2 9 Power switch Turns on off power to auxiliary circuits 5 10 Table 5 3 Front Panel Controls and Indicators S Model A description of the function of the LEDs and the power switch are given in section...

Страница 33: ...nnector 5 12 3 4 Coolant Water Out NPT male threaded coolant outlet pipe 5 12 2 5 Cooling Fan Input section cooling fan 5 12 4 6 Interlock Power On Terminal strip External interlock and remote power o...

Страница 34: ...power on functions to be controlled The interlock terminals should be connected to any safety interlock circuitry in the power supply installation The remote power on terminals are wired in series wi...

Страница 35: ...etails 5 13 REAR PANEL LAYOUT S Models The 303S rear panel is almost identical to the 303L except these is no SLAVE or INHIBIT BNC connector If a number of units are to be connected in parallel a dais...

Страница 36: ...CONTROLS INDICATORS CONNECTORS 5 14 NOTES...

Страница 37: ...and load connections have been correctly made and the high voltage cable properly terminated at the load the power supply is ready to op erate NOTE The 203 303 series power supplies are not designed t...

Страница 38: ...wer supply is inhibited from charging 4 END OF CHARGE LED O Open collector Low impedance when power supply reaches End of Charge 5 EXCESS REVERSAL O Open collector Low impedance when EXCESS REVERSAL i...

Страница 39: ...t first be connected to a master supply or an appropriate control system 6 2 1 Remote Control Signals There are two recommended remote control signal arrangements for the 203 303 sup ply The first uti...

Страница 40: ...READY READY INPUT POWER FAULT AUTO DWELL INHIBIT END OF CHARGE OVERLOAD EXCESS REVERSAL COOLANT WARNING COOLANT FAILURE LOW COOLANT OR TEMPFAULT OVER VOLTAGE PURGE PUMP ARC DIGITAL GROUND AUTO DWELL I...

Страница 41: ...BLE 0V 10V VANALOG 0V AUTODWELL Figure 6 2 Remote Interface waveforms for 303 operated with AUTODWELL 6 2 3 Remote Operation with INHIBIT Although the AUTODWELL signal offers the user the simplest rem...

Страница 42: ...least one model 203 303L is connected in a parallel system then the system can be operated without an external controller by using the 203 303L as a master supply in local mode If status voltage and c...

Страница 43: ...a single L model should be oper ated as a master in either local or remote mode The other parallel supplies can be con nected to the SLAVE 25 pin D sub connector on the master unit rear panel refer t...

Страница 44: ...nal Control System L Model Parallel System L S Model Parallel System S Model Parallel System 30 20 10 0 5 10 15 20 25 30 30 20 10 0 5 10 15 20 25 30 30 20 10 0 5 10 15 20 25 30 30 20 10 0 5 10 15 20 2...

Страница 45: ...me this manual was produced These documents are continually being improved and expanded to always check for the latest revison on line APP Note 500 Calculating Capacitor Charge Time APP Note 502 Calcu...

Страница 46: ......

Страница 47: ......

Страница 48: ......

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ......

Страница 53: ...An Invensys company...

Страница 54: ......

Страница 55: ......

Страница 56: ......

Отзывы: