background image

Lambda Labs - Professional Acoustics                                                                                                                                           KW-18 Amplifier Rack Manual

3. Introducing

 

KW-18

 

Amplifier

 

Rack

 

3.1.

 

Introducing

 

KW-18

 

Amplifier

 

Rack:

 

External

 

Components

 

3.1

 

Figure

 

1:

 

KW-18

 

Amplifier

 

Rack

 

Overview

 

(Delivery

 

State)

 

www.lambda-labs.com 

!

9

a)

b)

c)

d)

e)

PART

DESCRIPTION of 3.1 Figure 1

REFERENCE

a)

Touring

 

Label

 

A

 

metal

 

plate

 

to

 

attach

 

a

 

touring/production

 

label.

 

_

b)

Wheel

 

Stacking

 

Recess

  

4

 

Wheel

 

Stacking

 

Recesses

 

allow

 

for

 

a

 

convenient

 

stacking

 

of

 

up

 

to

 

3

 

Lambda

 

Labs

 

KW-18

 

Amplifier

 

Racks

 

on

 

top

 

of

 

each

 

other!

 

NOTE:

 

Do

 

not

 

stack

 

more

 

than

 

3

 

Lambda

 

Labs

 

KW-18

 

Amplifier

 

Racks!

_

c)

Handle

 

To

 

carry

 

and

 

move

 

the

 

rack,

 

two

 

spring

 

loaded

 

Handles

 

can

 

be

 

found

 

on

 

both

 

sides

 

of

 

the

 

Lambda

 

Labs

 

KW-18

 

Amplifier

 

Rack

.

_

d)

Sliding

 

Door

 

with

 

Parking

 

Position

 

For

 

quick

 

front

 

and

 

rear

 

access,

 

2

 

slidable

 

doors

 

with

 

lock

 

and

 

internal

 

parking

 

position

 

can

 

be

 

found

 

on

 

both

 

sides

 

of

 

the

 

Lambda

 

Labs

 

KW-18

 

Amplifier

 

Rack.

Chapter

 

3.2.1

e)

Brakeable

 

Transport

 

Wheels

 

4

 

rotatable

 

and

 

brakeable

 

Transport

 

Wheels

 

allow

 

for

 

a

 

comfortable

 

transport

 

of

 

the

 

rack.

 

To

 

brake

 

the

 

wheels,

 

please

 

only

 

use

 

your

 

feet,

 

wearing

 

appropriate

 

protective

 

shoes.

 

_

Содержание KW-18

Страница 1: ...W 18 Amplifier Rack Manual Version 1 1 KW 18 Amplifier Rack Manual Version 1 1 08 2020 2020 Lambda Labs All rights reserved This manual is optimized to save paper and to print 2 pages per DIN A4 sheet...

Страница 2: ...onents 11 4 Power Distribution Detailed Description 14 4 1 Power Distribution Detailed Description Front View 14 4 2 Power Distribution Detailed Description Rear View 15 4 3 Power Distribution Cable L...

Страница 3: ...Lambda Labs Professional Acoustics KW 18 Amplifier Rack Manual NOTES www lambda labs com 2...

Страница 4: ...repared to the best knowledge and with the utmost care Lambda Labs can not guarantee the accuracy of the documentation in all cases Lambda Labs disclaims any liability for any errors or omissions that...

Страница 5: ...amage in the equipment and risk of electric shock Use only attachments accessories specified by the manufacturer No user serviceable parts inside Do not remove the top cover or the rear section of the...

Страница 6: ...d not be connected or disconnected under load or live Setup environment Keep the device dry and avoid the contact to heavy dust salt sand and prolonged exposure to intense sunlight or strong vibration...

Страница 7: ...repair or exchange parts by yourself and without support of a qualified service personnel Manual Keep this manual within easy reach for operating the product s all the time As a Lambda Labs products...

Страница 8: ...the unit PE impedance should be always kept low The use of a GFCI unit is recommended In the case of single phase power line application use a common single phase GFCI In the case of three phase power...

Страница 9: ...sets Reference Guide The main features of the KW 18 Amplifier Rack 19 10 RU shock mount amplifier rack 4 pieces of braked 100mm heavy duty wheels 4 pieces of handles 2 slidable doors with internal par...

Страница 10: ...Labs KW 18 Amplifier Racks on top of each other NOTE Do not stack more than 3 Lambda Labs KW 18 Amplifier Racks _ c Handle To carry and move the rack two spring loaded Handles can be found on both si...

Страница 11: ...y up www lambda labs com 10 Danger Do not stack more than 3 Lambda Labs KW 18 Amplifier Racks on top of each other Always brake the wheels of all KW 18 Amplifier Racks when stacking them Danger The Ha...

Страница 12: ...eat the steps for the rear door Never operate the amplifiers with closed doors 3 3 Introducing KW 18 Amplifier Rack Internal Components 3 3 Figure 1 KW 18 Amplifier Rack Front Overview Delivery State...

Страница 13: ...he KW 18 units _ d Signal Distribution Front Side The 19 2 RU Signal Distribution provides 8 pole 4 pole and 2 pole Speakon Outputs Additionally it provides Dante AES Analogue Inputs and Ethernet Remo...

Страница 14: ...ifiers or 3rd party amplifiers with daisy chain outputs Cables are not depicted in the illustrations All cables are labeled Chapter 5 c Power Distribution Rear Side The 19 2 RU Power Distribution prov...

Страница 15: ...se always rack screws equipped with plastic washer to avoid damage of the KW 18 surface Caution Never operate the amplifiers with closed doors Both doors need to be open while operating the amplifiers...

Страница 16: ...4 3 Chapter 6 c Auxiliary 230V 2 x 6A Socket AUX Power outlets for Auxiliary devices Ethernet Switch DSP etc Chapter 4 1 4 3 Chapter 6 d L1 L2 L3 POWER INDICATOR LAMP Indicators for voltage present o...

Страница 17: ...d Pinout please refer to Chapter 8 Chapter 5 2 5 3 Chapter 6 Chapter 8 d AMP 1 OUT 2 4 pin Neutrik Speakon output from Amplifier 1 Channel 2 Top Amplifier Unit For detailed Pinout please refer to Chap...

Страница 18: ...6 Chapter 8 k SIGNAL INPUT Analogue or AES EBU Signal input for the Amplifier Rack For detailed Pinout please refer to Chapter 8 Chapter 5 2 5 3 Chapter 6 Chapter 8 l SIGNAL OUTPUT Daisy Chain Analog...

Страница 19: ...Chain Ethernet Output Connector 1000MB S for connecting additional Amplifier Rack s _ e AmpRack Analogue AES Inputs Input Audio A Chapter 5 1 5 3 Chapter 6 8 f AmpRack Analogue AES Inputs Input Audio...

Страница 20: ...lifier 2 Channel 1 Channel 5 Channel 2 Channel 6 Channel 3 Channel 7 Channel 4 Channel 8 Amplifier Rack Analogue AES Inputs Amplifier Rack Dante Ethernet IO Input Channel A Dante Primary Input Channel...

Страница 21: ...ctors MultiLink Breakout Cable 5m 5m shielded 4 pair AES compatible cable with one female 12 pin IP68 WEIPU Connector and 4 pieces of Neutrik Gold Plated XLR female Connectors MultiLink Coupler 0 15m...

Страница 22: ...onnectors 8 Pole Speakon Cable 0 7m 0 7m 8 x 4mm2 High Quality Speaker Cable with 2 pieces of Neutrik NLT8FX BAG Connectors 8 Pole 2x4 pole Sub Speakon Breakout Cable 5m 4 pieces of 2 x 2mm2 5m cables...

Страница 23: ...ger Risk of Electric Shock Clean the Amplifier Rack with unplugged Power and Signal cables ONLY Caution For cleaning use a soft slightly wet cloth eventually with a bit of Dishwasher Do not use excess...

Страница 24: ...nal Acoustics KW 18 Amplifier Rack Manual 8 Appendix 8 1 12 Pole MultiLink WEIPU Pinout www lambda labs com 23 Function PIN Number CH1 1 CH1 2 CH2 3 CH1 GND 4 CH2 5 CH3 6 CH2 GND 7 CH3 GND 8 CH4 GND 9...

Страница 25: ...s KW 18 Amplifier Rack Manual 8 2 8 Pole Neutrik NLT8MX BAG Pinout 8 3 4 Pole Neutrik NL4FC Pinout www lambda labs com 24 Function PIN Number CH1 1 CH1 1 CH2 2 CH2 2 CH3 3 CH3 3 CH4 4 CH4 4 Function P...

Страница 26: ...Lambda Labs Professional Acoustics KW 18 Amplifier Rack Manual 9 Dimensions www lambda labs com 25 Dimensions mm Weight 79 kg 174 2 lbs 710 565 560 690 560...

Отзывы: