2. Dispensing Amount of Double Cups
Hold and press the double cup (2 cup) button for 3 seconds to enter into the mode
setting for the dispensing amount, then follow the operation of setting the dispensing
amount of single cup. The adjustable dispensing amount of double cups ranges
between 50ml and 100ml, the working duration for this setting is a maximum of
90 seconds.
If working duration for double (2 cup) coffee is set, working duration for single cup
(1 cup) will be automatically updated to half of that for 2 cup coffee
3. Restore Factory Setting
Simultaneously hold and press the double cup (2 cup) and steam button buttons for
3 seconds, the corresponding icons will blink 3 times, to recover to the factory setting
of the appliance.
AUTOMATICALLY POWER-OFF FUNCTION
1. If there is not any operation within 25 minutes, the unit will power off automatically.
2. If there is not any operation after the pump has worked for 60 seconds making hot
water, the unit will power off automatically.
3. If there is not any operation after the pump has worked for 5 minutes, making steam
the unit will power off automatically.