Adjustable Exhaust Grille
Large adjustable exhaust grille with individually
adjustable vanes allows a variable air-flow to be
presented to the room according to size and traffic
pattern.
Safety Interlock System
Located in the channel behind the collecting cell, the
micro-switch controlled interlock system will not allow
operation of the LAFC without having the intake panel
locked into place.
Variable Speed Control
The LAFC-RC2 is equipped with a variable speed
control that can be mounted on the unit or at a wall
switch. This allows a great range of air circulation and
noise control.
System Light
The LakeAir LAFC is fitted with a sys-tem
light which indicates when your air cleaner is in
operation. Located below the three-position
switch, the light will be lit when all system
connections are activated.
Piggyback Fuse System
The unit is provided with a fused circuit that
protects valuable components in case of a
power surge. An additional “piggyback” fuse is
located in the fuse holder for easy access if it is
needed.
HOW YOUR LakeAir MODEL LAFC WORKS
In business establishments or public buildings, millions of airborne particles are continually being circulated
in the air you breathe. Your LakeAir Model LAFC Self Contained Flush Mounted Electronic Air Cleaner
removes the smoke, dust, dirt, pollen, and other pollutants from the air with an electrostatic process which
works this way:
1.
The internal circulating blower mechanism
draws the
dirt laden
air into the system where
it first encounters the
outer PREFILTER
SCREEN.
2.
The PREFILTER SCREEN collects the
larger
particles from the
air and holds them on
its intermeshed
surface.
3.
In electronic units, the air then passes into
the
ELECTRONIC
FILTER CELL where it
first meets the
IONIZING SECTION with
its
many fine ion wires.
These wires charge the
airborne particles
by exciting
them with a high
electrical charge. As the charged
particles
move along to the COLLECTING SECTION,
they are
trapped by the collector plates much
like a
magnet attracts and
collects metal fil-ings.
4.
In HEPA LAFC units, the air is drawn
through a high
efficiency,
commercial grade true HEPA mini pleat
system. The harmful particles are held by the tightly knit
material.
5.
The ACTIVATED CARBON AFTER-FILTER, the
final filter in the
system,
removes odors and freshens
the air.
6.
The cleaned and purified air is then
returned to the
room environment.
5
Activated Carbon
Afterfilter
Electronic
Filter Cell or
HEPA Media
Pad Filter Cell
Prefilter
Screen
Dirt Laden Air
Clean Fresh Air