background image

OPERATING AND SERVICE  

INSTRUCTIONS 

RK Ventures Inc

 

www.lakeair.com 

LA2

-RC

2

-HUV

 

Warning  this product utilizes

Germicidal UV which maybe

Dangerous

Содержание LA2-RC2-HUV

Страница 1: ...OPERATING AND SERVICE INSTRUCTIONS RK Ventures Inc www lakeair com LA2 RC2 HUV Warning this product utilizes Germicidal UV which maybe Dangerous...

Страница 2: ...e 4 Location of units in a room Page 5 Mounting the LA2 RC1 HUV Page 5 6 Operating Instructions Page 6 Filter and bulb replacement Page 7 10 Repair and maintenance Page 11 Trouble Shooting Page 12 Rep...

Страница 3: ...aps dirt smoke mold bacteria and viruses These particles can be as small 1 Micron 3 An Activated Carbon filter then removes odors gases and harmful VOCs 4 The virtually clean air then passes through a...

Страница 4: ...he LA2 RC1 HUV uses a variable speed controller to provide between 300 and 800 cubic feet minute You should calculate the cubic feet of air in the area to be cleaned and then use a figure of 6 air cha...

Страница 5: ...2 RC2 HUV HEPA UV Air Purifier The primary objective HEPA UV air purifiers is to interrupt the transmission of air borne infectious pathogens within the indoor environment These models should be insta...

Страница 6: ...lectrical power to the unit Caution Ultraviolet Energy Protect Eyes and Skin Before operating this unit read all instructions Be sure you follow all safety precautions listed in this manual and on saf...

Страница 7: ...and UV Bulb Replacement NOTE FAILURE TO Change Filters and Bulbs May Create a Hazard Carbon Filter HEPA Filter UV Bulbs Every 6 months Every 3 months Annually Pre Filter Wash every 4 month replace an...

Страница 8: ...orb harmful VOCs and they act as an UV Ray Shield NEVER run the UV unit without Carbon filters installed Serious damage can happen if people are exposed to unshielded UVC rays The carbon filters surro...

Страница 9: ...n filters Harmful UV rays will be allowed to escape the unit Re assemble the UV chamber and place the completed chamber with both UV Carbon filters and UV cell next to the HEPA filter as shown Note th...

Страница 10: ...fluorescent lamps Some lamps may need to be treated as hazardous waste and not discarded with regular waste although low mercury lamps may be an exception however check state and local codes for prope...

Страница 11: ...performed by a trained experienced serviceman Check with your dealer for the repair station in your area If unable to locate a qualified serviceman contact the factory at the address or telephone num...

Страница 12: ...d number of test points INDICATOR LIGHT DOES NOT WORK 1 Check fuse 2 Plug power supply into the proper receptacle 3 Measure line voltage at power source 120V depending on unit 4 Replace light UV Cell...

Страница 13: ...7592 LED Indicator 497546 Fuse Box 497657 Safety Interlock Switch 100690 Blower Capacitor 499300 UV Filter Cell 120121 UV Ballast 400270 UV Tube G15T8 810301 Activated Carbon Filter Kit 285300 UV Cell...

Страница 14: ...ELECTRICAL SCHEMATIC MODEL LA2 RC1 HUV LA2 RC2 HUV 11 14...

Страница 15: ...r dead layer of human skin thus minimizing the amount of UVC transmitted through the epidermis Although UV is far more energetic than the visible portion of the electromagnetic spectrum it is invisibl...

Страница 16: ...nit be sure all UV bulbs and ballasts have been removed and disposed in accordance with local regulations To be sure no one can accidentally hurt themselves by turning the unit on please cut the power...

Страница 17: ...LakeAir Electronic Air Cleaner or any part thereof which has not been operated in accordance with the operating instructions herein contained where components or other accessories not compatible with...

Отзывы: