10
EARTH AND GROUD
This unit is operated with an external wall plug adaptor and so is not
grounded by a 3-wire mains cord. The internal reference point (ground)
is connected to the case and may be lifted by means of a jumper (see
page 17). Sometimes it may be helpful to additionally connect the case
to an external earth/ground potential.
THE POWER SUPPLY
MPA RS 01 should be operated with the provided wall-plug adaptor, but
also any other USB supply is suitable.
However, because of the often relatively thin cables of these devices,
there might be a significant voltage drop on the cable which might impair
the proper operation of MPA RS 01.
Other USB power sources may be used under the following
circumstances:
- a proper DC voltage within the range of 5 – 5,5 V
- a current capacity of min 1 A
THE FUSE
The fuse of this appliance is soldered in place and accessible from the
inside only !!
A blown fuse may indicate an internal problem and should be replaced
during qualified servicing or repair works !!
CAUTION !!
MIND THE SAFETY INSTRUCTIONS:
A blown fuse indicates an internal fault and
should be replaced during qualified repair or
servicing only !!