Pinnacle
TM
100 Modem
Hosted Mode Low Power User Guide
https://www.lairdconnect.com/
37
© Copyright 2020 Laird. All Rights Reserved
Americas
: +1-800-492-2320
Europe
: +44-1628-858-940
Hong Kong
: +852 2923 0610
8.5
at+cpsms
at+cpsms=0
•
at+cpsms=1,,,"10100001","00001010" (Enable
,,,”T3412”,”T3324”)
•
0
– Disable the use of PSM
•
1
– Enable the use of PSM
T3412 Timer
Bit
8
7
6
5
4
3
2
1
Unit
Timer value
*Bits 5 to 1 represent the binary coded timer value and unit is coded by bits 8, 7, & 6 as below:
T3412 = “10100001”
101 = 1 min
00001 = 1
T3412 = 1 min x 1 = 1 min
T3324 Timer
Bits 8, 7 & 6 represent the Time Increment Unit per Table
Bits 5 to 1 represent the binary coded timer value and unit is coded as below:
T3324 = “00001010”
000 = 2 sec
01010 = 10
T3324 = 2 sec x 10 = 20 sec
8.6
at+cedrxs
at+cedrxs=0
(Disable)
at+cedrxs=1,4,5
(Enable,Cat-M1,81.92 sec)
at+cedrxs=1,5,5
(Enable,Cat-NB1,81.92 sec)
Bit
8 7 6
0 0 0 value is incremented in multiples of 10 minutes
0 0 1 value is incremented in multiples of 1 hour
0 1 0 value is incremented in multiples of 10 hours
0 1 1 value is incremented in multiples of 2 seconds
1 0 0 value is incremented in multiples of 30 seconds
1 0 1 value is incremented in multiples of 1 minute
1 1 0 value is incremented in multiples of 320 hours
1 1 1 value indicates that the timer is deactivated
Bit
8 7 6
0 0 0 value is incremented in multiples of 2 seconds
0 0 1 value is incremented in multiples of 1 minute
0 1 0 value is incremented in multiples of 10 hours
1 1 1 value indicates that the timer is deactivated