CL4490 User Guide
Version 3.0
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/ramp
29
Laird Technologies
11.
Configure the radios that will communicate with server #2 as
Client
and
Auto Destination
and
with the same RF Channel Number as server #2 (
). Click Write Radio to write the changes
to the radios EEPROM.
Figure 14: Client settings
12.
Repeat Step 10 for each server that needs to synchronize to the Hop Master; if the server will not
be in range of the Hop Master server, set its Sync to Channel to the RF Channel Number of
another synchronized server that is in range of the Hop Master (make sure the RF Channel Number
of the server is higher than the Sync to Channel).
13.
Repeat Step 12 for all clients that you wish to communicate with each server from Step 12.
I’ve configured my radios, what’s next?
Once you have configured all radios, set up your network similarly to the one shown in
. The main
server or Hop Master must be powered on anytime that the other servers are connected to enable them to
synchronize and communicate with their clients. If a centralized network does not work and all servers are
not in range of the Hop Master, use a daisy chain network as shown in