Set up the module into Direct Test Mode, you will need to retrieve two sets of four characters each which function as
a unique passcode to enter direct test mode. To retrieve the characters, issue the following command:
AT I 14
You should receive a response such as:
10
14
01
1234
5678
9ABC
Note the characters in the highlighted positions above. In our example in
, they are
CB71
and
7B03
.
Figure 3: Return from at i 14
To enter Direct Test Mode, using the characters you found in the previous steps, issue the AT+DTM command as
follows:
AT+DTM 0x
CB71
7B03
The module is now in Direct Test mode.