AC4868 868 MHz Transceiver
User’s Manual
Americas: +1-800-492-2320 Option 3
32
Laird Technologies
Europe: +44-1628-858-940
Hong Kong: +852 2923 0610
www.lairdtech.com/ramp
Parameter
EEPROM
Address
Length
(bytes)
Range Default
Description
Destination ID
0x70
6
0x00 –
0xFF
0xFF
Specifies destination for RF packets
System ID
0x76
1
0xE3,
0xFF
0xFF
Similar to network password. Radios must have
the same system ID to communicate with each
other.
RS-485 DE
0x7F
1
0xE3,
0xFF
0xFF
0xE3 = GO0 is active Low DE for control of
external RS-485 hardware
0xFF = Disable RS-485 DE
MAC ID
0x80
6
0x00 –
0xFF
Factory programmed unique IEEE MAC address.
Original Max
Power
0x8E
1
Set in
prod. ,
varies
Copy of original max power EEPROM setting.
This address may be referenced but should not
be modified.
Product ID
0x90
15
0x90 - 0x93: Product ID
0x94 - 0x95: Prefix (AC)
0x96 - 0x99: Power (250M)
0x9A - 0x9C: Interface (485, TTL)
0x9D - 0x9E: Setup script (01 is stock)
0x9F: Reserved for future use; always 0xFF
DES Key
0xD0
7
0x00 –
0xFF
56-bit Data Encryption key