Laird 455-0009 Скачать руководство пользователя страница 9

https://connectivity.lairdtech.com 

© Copyright 2019 Laird. All Rights Reserved 

Americas

: +1-800-492-2320 

Europe

: +44-1628-858-940 

Hong Kong

: +852 2923 0610 

 

 

 

The Sentrius mobile application allows a user to configure a device, troubleshoot a device, see real-time sensor data, and update 
firmware. Search the appropriate app store (

Google Play Store

, 

Apple Store, 

or

 

the

 Microsoft Store

for the Sentrius Sensor App 

and install it on your device.  

Note:

   This guide only contains a brief walkthrough. Refer to the RS1xx Guide for further details on sensor functionality and the 

mobile app capabilities. To access the RS1xx Guide, navigate to the 

RS1xx product page

click Documentation, and select 

the 

Sentrius RS1xx User Guide

The Sentrius sensor mobile app displays real-time sensor data from the external temperature probe and sensor once a good cable 
connection is established. 

To view real-time sensor data, follow these steps: 

 

Press and hold the BLE button 

 on the front panel of the sensor to start BLE advertising on the device. 

 

Select the corresponding DEV EUI on the connection screen of the mobile app. The DEV EUI of the sensor can be found 
on the back label of the sensor. 

 

Once connected to the mobile app, click the Temperature Reading icon 

 under the Temperature/Humidity section to 

see real-time sensor data from the temperature probe.  

From this screen, the temperature probe can be validated by confirming the temperature measurements are accurate. Place 
your hand on the probe to fluctuate the temperature.   

 

 

 

Figure 6: Sentrius sensor mobile app displays 

Update the sensor settings on the main screen 

  to get a faster reading period if the temperature readings are taking too long 

to update on the graph. The fastest read period a sensor can have is thirty seconds. 

Содержание 455-0009

Страница 1: ...A https connectivity lairdtech com 1 Copyright 2018 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 Version 1 0...

Страница 2: ...ch com 2 Copyright 2019 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 Version Date Notes Contributors Approver 1 0 07 Jan 2019 Initial Release Robert...

Страница 3: ...Hong Kong 852 2923 0610 1 Introduction 4 2 Part Numbers 4 3 Installation 5 3 1 Illustrations 6 3 1 1 Stainless Steel Temperature Probe with RJ45 Cable Assembly 6 3 1 2 RJ45 Cable Gland 7 4 Connection...

Страница 4: ...ctionality and the mobile app capabilities To access the RS1xx Guide navigate to the RS1xx product page click Documentation and select the Sentrius RS1xx User Guide Figure 1 Sentrius sensor with exter...

Страница 5: ...the Sentrius Sensor Screw on by hand the top portion of the cable gland the screw nut 3 until tight Visually check to ensure the lower portion of the cable gland the pressing screw 2 is also tight Fig...

Страница 6: ...onnectivity lairdtech com 6 Copyright 2019 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 Figure 3 Stainless steel temperature probe with RJ45 cable a...

Страница 7: ...https connectivity lairdtech com 7 Copyright 2019 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610 DIM in millimeters Figure 4 RJ45 cable gland...

Страница 8: ...from the Installation section Make sure the sensor has the latest firmware installed to ensure the sensor has all the latest capabilities The firmware can be updated using the mobile app Reference the...

Страница 9: ...he external temperature probe and sensor once a good cable connection is established To view real time sensor data follow these steps Press and hold the BLE button on the front panel of the sensor to...

Страница 10: ...https connectivity lairdtech com 10 Copyright 2019 Laird All Rights Reserved Americas 1 800 492 2320 Europe 44 1628 858 940 Hong Kong 852 2923 0610...

Страница 11: ...The average current consumption was 72 uA over 32 minutes The data rate that the RS186 transmitted at was SF7BW125 Every external temperature probe is cleaned with an alcoholic wipe and placed in an...

Отзывы: