4.3 Input/Output Settings
I/O
Input
Input setting items allows you to activate and select the functionality related to input. Input 1 has
options “Disable” and “Ignition”. Input 2 has options “Disable”, “Trigger”, and “Counter”.
Trigger setting
:
This option allows you to send an alert when the alert signal condition is
met on an Input. An alert is generated when the voltage level goes from
either a High to a Low or from a Low to a High. This setting is user
defined.
Counter setting
:
This option allows the user to implement input 2 as a counter. The counting
signal can be specified as either a Low to High (Low
High) or a High to
Low (High
Low) voltage level change. The maximum counting speed is
50 times per second, with minimum voltage change of last at least 10 ms.
Counter Start Value
: This option allows the device to record how many times the alert gets
triggered and accumulates from the value you set it to.
Counter Alert Value
: This option allows you to tell the Starfinder Lite to send an alert when the
counter value reaches a user defined value. If you set it to 90, it will send an
alert once the counter’s value reaches 90.