U.L. Caution

This pump has been tested using water only. Its suitability for use with liquids other than 

water is the end user’s responsibility.

Incorrect Installation Do not mount in these orientations

Pump Mounting Positions   fig. 3

Correct Installation

8. Close the shut-off valve on the inlet side of the pump and turn the water supply to 
the house back on.

9. Flush system of debris. 

Before reattaching the pump motor, open the shut-off valve on 

the inlet side of the pump housing and let water flow through the housing. Use a bucket to 
catch the water. Let the water run long enough to clear all sand, solder pellets, plumbers 
tape flakes, etc. from the lines. Close the inlet shut-off valve when finished.

10. Connect the pump motor to the housing.  

Make sure the rubber o-ring is in place 

in the housing and the screw ring is securely hand tightened (for 303 models) or that the 
top housing screws are firmly in place and tightened (909 models). 

Reopen the shut-off 

valve or valves and let the water flood the pump housing.

11. Purge air from the supply line. 

Turn on the faucet or shower farthest from the water 

heater. Open the line until you get a good, steady stream of water without sputter or evi

-

dence of air.

12. Purge air from the return line. 

Connect the pump to the electrical supply. With the 

pump running, open the hose bib and let water run until the pump is running quietly and 
there is no sputtering or other evidence of air coming from the hose bib. Close the hose 
bib. Your system is now in operation. Allow a few minutes for instant hot water to recircu

-

late to all of your faucets.

SAFETY PRECAUTION: 

Remove the handle from the hose bib(s) to prevent a small child 

from mistaking it for a cold water faucet.

Insulating 

both the hot water supply and recirculation lines is strongly recommended.

13. If you have an SMT or UCT timer pump, 

set your timer in accordance with the in

-

structions on the following page.

4

Or, if the Rotor/Im-

peller cannot be 
removed using 
forefinger and thumb, 

carefully lever off 
evenly with two 

screwdrivers.

4. Shut off the water to the house.

5. Drain the plumbing lines 

by opening the faucets in the house.  Drain the water heater 

if you plan to make the connection at the botom of the water heater, which requires re

-

moval of the drain valve.

6. Connect the return line at the last faucet riser and run to the water heater.  

Tee the 

return line as close to the end of the hot water supply line as possible and run the return 
line back to the water heater.

7. Install the pump and other compo-
nents required 

in accordance with the 

diagrams provided in fig. 1 or 2 and con

-

nect the return line to the water heater 

(also see fig. 3).

For SM(T) and UC(T) 303 Models
Check pump operation before you 
begin. 

Unscrew the pump housing from 

the motor (fig. 4) and run the pump 
for a few seconds to make sure it is 
operational. Remove the rotor (see fig. 
5) and add a little water to the bearing 
ball for lubrication. Do not use 
grease or oil to lubricate the pump.

Fig. 5

303-Models - Rotor/Impeller Installation: 

To remove the rotor unit, grasp the top of the unit 

and gently pull straight up. Do not pull up on one side only or push the rotor sideways. If the 
rotor sits too tightly, carefully lever it off with a screwdriver on each side of the rotor.  When re-
installing the rotor, use enough force to hear the rotor “click” on to the ceramic bearing and spin 
the rotor with your fingers to insure that it turns freely.

For SM(T) - 909 Models

This unit may be installed into the pipe system without disassembling the pump.
However, it is recommended that the motor section be disassembled from the pump 
housing by removing the two pump housing screws so that the system may be flushed as 
noted in paragraph 9.

Remove the Ro-

tor/Impeller by using 
forefinger and thumb 
and pulling upward.

Fig. 4

Remove the mo-

tor unit and 

o-ring from the 
pump housing 

into the plumbing 
line.  Do not 

sweat the housing 

into the plumbing 

line with the motor 

or o-ring attached. 

Arrows on the 
pump housing 

indicate the direc

-

tion of water flow.

Caution: Only hand tighten the screw ring. Do not over 
tighten! Do not use plumbers putty on the screw ring.

Ultracirc Models

The UC and UCT-303 models incorporate a shut off valve and check valve into the brass 
pump housing eliminating the need to install these components.

These models are supplied with 1/2” union fittings. These fittings should be removed from 
the pump housing before soldering to avoid damaging the internal valves.

Shut-Off Valve (allows isolation of water in the tank in the event of pump servicing).

Hose Bib (allows venting of air from system at start-up).

Auto Air Vent (allows continuous venting of air bubbles that intrude into all hot water circu

-

lating systems during operation).

Содержание SM-303-B

Страница 1: ...mmediately after the pump is turned off During normal operation an occasional air bubble may pass through the pump housing causing a momentary gurgling noise However if noise at the pump persists for any prolonged period correct the problem see below The check valve is mistakenly installed on the inlet side of pump or in the wrong direction The inlet side shut off valve is closed or clogged There ...

Страница 2: ...ufficient to overcome the friction losses created by the piping in the house water sup ply line and the return line Oversized Pumps Pumps should not be so large as to produce flow rates that may eventually erode holes in the pipes According to the Copper Development Association excessive erosion occurs at a velocity of about 5 ft per second and higher or about 4 GPM in 1 2 Type M copper pipe and 8...

Страница 3: ...ufficient to overcome the friction losses created by the piping in the house water sup ply line and the return line Oversized Pumps Pumps should not be so large as to produce flow rates that may eventually erode holes in the pipes According to the Copper Development Association excessive erosion occurs at a velocity of about 5 ft per second and higher or about 4 GPM in 1 2 Type M copper pipe and 8...

Страница 4: ...e drain valve 6 Connect the return line at the last faucet riser and run to the water heater Tee the return line as close to the end of the hot water supply line as possible and run the return line back to the water heater 7 Install the pump and other compo nents required in accordance with the diagrams provided in fig 1 or 2 and con nect the return line to the water heater also see fig 3 For SM T...

Страница 5: ...e drain valve 6 Connect the return line at the last faucet riser and run to the water heater Tee the return line as close to the end of the hot water supply line as possible and run the return line back to the water heater 7 Install the pump and other compo nents required in accordance with the diagrams provided in fig 1 or 2 and con nect the return line to the water heater also see fig 3 For SM T...

Страница 6: ...when ordering Model number Serial number Part description 6 Do install an air vent mounted in a vertical position if provided use 1 2 recirculation line tubing check to be sure there are no crimps or sharp bends in the recirculation line that would restrict the flow be sure the check valve is installed in the proper direction of the flow be sure all air is purged from the system prior to starting ...

Страница 7: ...when ordering Model number Serial number Part description 6 Do install an air vent mounted in a vertical position if provided use 1 2 recirculation line tubing check to be sure there are no crimps or sharp bends in the recirculation line that would restrict the flow be sure the check valve is installed in the proper direction of the flow be sure all air is purged from the system prior to starting ...

Страница 8: ...ng noise immediately after the pump is turned off During normal operation an occasional air bubble may pass through the pump housing causing a momentary gurgling noise However if noise at the pump persists for any prolonged period correct the problem see below The check valve is mistakenly installed on the inlet side of pump or in the wrong direction The inlet side shut off valve is closed or clog...

Отзывы: