Rinse pump and impeller after every use.
MAINTENANCE
To avoid injury, do not touch moving or hot parts.
Always unplug all appliances from outlet when not in use, before
putting on or taking off parts and before cleaning.
The motor is hermetically sealed and filled with epoxy, thereby
requiring no lubrication or other maintenance.
Although the impeller cavity is self cleaning, regular maintenance is
required.
Remove the Statuary Pump from the installation.
Disassemble the complete impeller cavity by first removing the
motor cover.
Removing the motor cover:
Statuary Pumps 1, 2 & 3 : No tools are needed to remove the pump
base and motor cover.
Statuary Pumps 2 & 3 : Once the motor cover is off, move arrow on
the Impeller Cover counterclockwise to the “OFF” position and lift
out Impeller Cover.
Removing the impeller and
ceramic shaft assembly:
To remove Ceramic Shaft
Assembly, insert the hooked end
of the supplied tool into the hole
near the bottom of the unit, draw
the entire assembly up and out.
(Fig. 1)
IMPELLER MAINTENANCE
WARNING:
The motor units incor-
porate a ceramic impeller shaft. This shaft will provide reliable, last-
ing performance. However this shaft is brittle. Please take extreme
care when cleaning. Replacement shafts are available.
Thoroughly clean all parts to remove accumulated slime, dirt or debris.
Fig. 1