Troubleshooting Guide
Problem
Possible Cause / Solution
Startup
Maintenance
A) Does not foam properly
B) Using too much chemical
1, 2, 3, 4
5
6
6
Possible Cause / Solution
Startup
Maintenance
1. GPM too low
See requirements.
2. Wand solution inlet clogged
Clean the wand solution inlet. DO NOT DRILL OUT
3. Ensure chemical is recommended for foaming and/or the
application
See chemical manufacturer.
4. Dilution too weak / Chemical is very thick.
Adjust injector at the pressure washer/pump
5. Dilution too strong
Adjust injector at the pressure washer/pump
6. Chemical injector at the pressure washer may be
malfunctioning
Consult pressure washer manual
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out
of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical strainer and replace if missing.