ELECTRONIC VOICE REACTION TIMER

4

4

Latching/Sequential Mode

If the Latching/Sequential Mode is selected the next message to be displayed is the following;

VOL  QUIT    RUN

If the microphone sensitivity settings are to be changed, the button directly under the

 VOL

 should

be pressed. If you wish to leave this mode, press the button under 

QUIT

. If the mode and settings

are satisfactory, and you wish to begin testing, press the button under 

RUN

.

If the sensitivity is to be adjusted, the following screen will appear on the display;

PICK  MICROPHONE
 MIC1    MIC2     OK

Select the microphone that you wish to adjust by pressing the button underneath 

MIC 1

 or 

MIC 2

.

This will bring up a new screen in which the current sensitivity setting is displayed in percentage
of maximum sensitivity and the following choices will be displayed;

  INC   DEC     OK

Pressing the 

INC

 button will increment the sensitivity in 1% increments. If the button is held down,

the sensitivity will increment at a moderate rate for the first five increments, and then will
increment at a much faster rate, until the button is released. The same is true for the 

DEC

 button,

except that the sensitivity will decrement. Once the sensitivity setting for that microphone is at the
desired value pressing the 

OK

 button will bring you back to the 

PICK MICROPHONE

 screen.

Pressing the 

OK

 button will take the user back to the previous screen.

If all the settings are acceptable, pressing the 

RUN

 button will allow testing to begin. The LCD

displays the following screen;

REAC   TIME=0.000S
     VOL     QUIT

At this point, a trigger input from microphone 1 will cause four things to occur. First, Relay 1
contacts will close and latch and the green indicator LED for input 

mic 1

 will turn on.  At the same

time, Relay 3 contacts will close and the reaction time display will start running. Pressing the

QUIT

 button at this point will open relay 1 and 3 contacts, shut off the green LED, and reset the

clock.  If the 

QUIT

 button is not pressed, the clock will continue to run until a input

 mic 2

 trigger is

received. At this point, Relay 2 contacts will close latch while Relay 3 contacts open and the clock
display stops running. Again, pressing the 

QUIT

 button at this point, will open all closed relays,

turn off the indicator LEDs, and reset the clock display.  If the 

QUIT

 button is pressed again, you

will leave this mode of operation, and be taken back to the latch mode selection screen.

When in this mode, the microphone sensitivity can still be adjusted, but only when no relays are
closed. Once a relay closes, the 

QUIT

 (reset) button must be pressed before sensitivity

adjustments can be made.

1.

2.

3.

4.

Содержание 63040A

Страница 1: ...3700 Sagamore Parkway North P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com Model 63040A ELECTRONIC...

Страница 2: ...hone or a manual pushbutton all of which are supplied with each unit A microprocessor is employed to provide overall control of the unit s functions It operates in four different modes which are Latch...

Страница 3: ...ds selectable in 10 millisecond increments This is further described in Non latching Sequential Mode instruction 6 pg 5 Once the type of latching mode is determined the next message to be displayed wi...

Страница 4: ...the sensitivity setting for that microphone is at the desired value pressing the OK button will bring you back to the PICK MICROPHONE screen Pressing the OK button will take the user back to the prev...

Страница 5: ...ting can immediately begin Since this is a sequential mode of operation microphone 1 must produce a trigger input before microphone 2 s input will become valid If microphone 1 has produced a trigger a...

Страница 6: ...k to the previous screen where the other relay may be selected for adjustment or the OK button can be pressed and testing may begin When the INC or DEC button is pressed and held the delay value will...

Страница 7: ...mail info lafayetteinstrument com Model 63040A User s Manual 7 7 System Specifications Power Supply 12VDC Power Consumption 0 75W Frequency Response 50 7000Hz 10mVRMS Sensitivity 4 0mV Output 3 sets...

Страница 8: ...d along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative authorizing the return An estimate of repair will be given prior to complet...

Отзывы: