71
Manikin Setup
System Setup
Sim
ulation Setup
Clinical F
eatur
es
Maintenance
Tr
oubleshooting
Spar
e Par
ts
Troubleshooting
Main Specifications
Size, weight
Dimensions (manikin only):
1800mm (l) x 550mm (b) chest
(5.90 ft x 1.80 ft)
Weight (patient manikin only): 38,5kg (85 lbs)
Weight (with clothes)
40 Kg (88 lbs)
Manikin power
External power:
Input voltage 24VDC, 6.25A
Internal batteries (two):
Each 14.8V, 4.6Ah, Lithium-Ion
Only use the SimMan Essential external power supply and
batteries.
Air & CO
2
Pressure
Internal fluid reservoir:
Max 0.9 bar
External air connection:
Max 1.4 bar
External CO
2
to manikin:
Max 1.4 bar
Temperature Limits
Operating temperatures:
+4 ºC to 40 ºC (39 ºF to 104 ºF)
Storage temperatures*:
-15 ºC to 50 ºC (5 ºF to 122 ºF)
* Requires that the fluid tanks and system is filled with 60%
Isopropanol or 70% EtOH
Environment - Manikin only
Relative humidity: 20% -90% (non-condensing)
DO NOT use outdoors in wet conditions.
Not tested with salt spray.
RF Communication
WLAN frequency ranges:
2.4 GHz WLAN, channels 1-11.
5 GHz WLAN, channels 36 - 64,149 - 165.
Operation range: 100 m (300 ft) max.
Material Chart for Manikin
Clothes:
Cotton, Nylon
Skins and airways PVC (DEHP free)
External hard plastics: PP, PA, PC, PC/PET
Inner plastics:
Silicone, TPU, TPE, PVC, Nitrile
PA, PA+GF, PC, ABS, POM, HDPE, PET,
Epoxy-Polyurethane
Metal components: Aluminum, Brass, Steel
Minimum Hardware Requirements for use
with SimMan Essential tablet PC’s)
• Core 2 Duo or better
• 1 GB RAM (2 GB recommended)
• 1GB hard disk space,
• 1024x768, 1280x800, 1280x1024 or better
• 16bit color resolution or better
• 100% DPI required
• Optical drive required for installation
Minimum Software Requirements
• Windows XP or Windows 7
• DotNet 3.5.1
ACCEPTABLE FLUIDS FOR MANIKIN
Cleaning Fluids
To clean the manikin’s fluid system use one of the following:
• 60% Isopropanol alcohol
SIMULATED IV FLUIDS
Only use purified water to simulate IV fluids:
• Distilled Water
• Deionized Water
Regulatory Information
FEDERAL COMMUNICATIONS COMMISSION STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received, including
interference that may cause undesired operation.
CAUTION
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and
receiver.
•
Connect the equipment into an outlet on a
circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV
technician for help.
The product is in compliance with Council Directive
2011/65/EU on Restriction on the use of certain hazardous
substance (RoHS).