Cautions and Warnings
A Caution identifies conditions, hazards, or unsafe practices that can result in minor personal
injury or damage to the Resusci Anne Advanced SkillTrainer.
A Warning identifies conditions, hazards, or unsafe practices that can result in serious personal
injury or death.
Airway
Caution
The use of silicon or any other lubricant not approved by Laerdal may cause damage
to the airway.
Notes
Electronic components are mounted inside the manikin's head. The following
techniques should not be performed on this manikin due to the inability to properly
sanitize the airway if they are performed:
• Mouth-to-mouth/Mouth-to-mask ventilation.
• Insertion of simulated vomit for suctioning.
Pulses
Note
Do not use excessive force when palpating the carotid pulse as this will result in no
pulse felt.
IV-Arm
Note
If training session involves administration of fluids and/or drugs, empty arm immediately
following session. This to avoid damage/stains on manikin while stored.
Defibrillation
Caution
• Defibrillation must be performed over the two defib connectors only. Paddle
adapters are supplied for use with manual defibrillators.
• Only apply the defibrillator to a defibrillation chest skin which is properly mounted
on the manikin's chest.
• Do not provide more than 2 x 360J defibrillator discharges per minute as an
average over a period of time to prevent overheating.
• The manikin chest must be kept dry. Special attention should be taken when using
IV Arm.
• Do not apply conductive gel or conductive defibrillation pads intended for patient
use to prevent chest skin pitting.
• Do not use cables or connectors with visible damage. Observe all normal safety
precautions for use of defibrillators.
Testing
Notes
• This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation.
• This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, it may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
• If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
–
Reorient or relocate the receiving antenna.
–
Consult the dealer or an experienced radio/TV technician for help.
–
Increase the separation between the equipment and receiver.
–
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
–
The use of shielded I/O cables is required when connecting this equipment to any and all
optional peripheral or host devices. Failure to do so may violate FCC rules.
General Caution
Changes or modifications not expressly approved by Laerdal Medicial could void the
user’s authority to operate this equipment.
Troubleshooting
Electromagnetic radiation from other radio transmitters or other electronic equipment
may cause noise in the head speaker. To eliminate this noise move manikin away from the
radiation source or turn the head speaker volume to zero.
ENG