background image

20

Preparing for Simulation - Change Eyes

3

4

1

2

Use different pupils to simulate various patient conditions.

Содержание Resusci Anne

Страница 1: ...www laerdal com Resusci Anne Simulator User Guide EN...

Страница 2: ...2...

Страница 3: ...Container 15 IV Arm 16 Lubrication 17 IOTibia 18 Change Eyes 20 Use Defibrillation 22 ECG Monitoring 24 Connections 25 Ventilation 26 Chest Compressions 27 Blood Pressure BP Arm 28 IV Arm 29 Intramus...

Страница 4: ...ion is designed for use with ShockLink RA Sim Paddle version is designed for use with defibrillator delivering high voltage in to the manikin paddle plates Note Illustrations may vary from product RA...

Страница 5: ...ect to SimPad PLUS or other PC orTablet applications Note Visit www laerdal com to download SimPad PLUS User Guide Operating Systems SimPad PLUS LLEAP Compatible systems Laerdal Simulation Home Voice...

Страница 6: ...tems Included 6 Reservoir bag Extrication Rescue Legs Clothes RA Sim Paddle version Training Pads included with the AED Link version ShockLink included with the AED Link version RA Sim AED Link versio...

Страница 7: ...nt Blood Pressure BP Cuff 3 Eye Sets normal constricted dilated pupils Microphone Headset and 2nd Microphone LAN Cable Microphone Extension Cable Full body soft pack AC Adapter and extention cable USB...

Страница 8: ...IV Arm BP Arm Main Panel IOTibia Airway Head ECG connectors Pulses Vocal Sounds Lung Sounds Heart Sounds IM Sites Note IV Arm and BP arm can be reversed in alternative configuration BP left IV right a...

Страница 9: ...ures Live defibrillation AED Link version with use of ShockLink Defibrillation with paddles Paddle plate configuration Automatic rhythm change after defibrillation ECG monitoring and Extensive ECG lib...

Страница 10: ...10 Charging Charge battery using AC Adapter complete with extention cable Fully charge battery before first use Use AC adaptor with extension cable to charge...

Страница 11: ...11 Power Panel Manikin starting Manikin is on Manikin is visible for SimPad Manikin is connected to SimPad...

Страница 12: ...12 Setup Attach Legs 1 2 3 4...

Страница 13: ...13 5 6 Setup Attach Legs Note To remove legs reverse procedure...

Страница 14: ...14 Preparing for Simulation Connect Microphone 1 2 3 4...

Страница 15: ...f spontaneous breathing is activated and no chest rise is observed ensure there is enough air in the air container Refill as necessary Air container is located inside pelvis Use manual pump provided o...

Страница 16: ...16 Preparing for Simulation IV Arm 16 Attach IV tubing to IV bag Allow fluid to flow through arm and out of other vein Use clamp to stop flow...

Страница 17: ...ET tubes before insertion Note Head contains electrical components Due to inability to sanitize airway mouth to mouth mouth to mask ventilation should not be performed Cautions Use only Laerdal Airway...

Страница 18: ...18 Preparing for Simulation IOTibia 1 2 3 4 5 6...

Страница 19: ...19 Preparing for Simulation IOTibia 30 35ml 7 8 9 10 11 12...

Страница 20: ...20 Preparing for Simulation Change Eyes 3 4 1 2 Use different pupils to simulate various patient conditions...

Страница 21: ...21 Preparing for Simulation Change Eyes 7 8 5 6...

Страница 22: ...g ShockLink andTraining Pads The SimPad PLUS LLEAP extensive ECG library will overide the internal ShockLink ECG library Caution Defibrillation training must be performed using ShockLink only Refer to...

Страница 23: ...ation must be performed over the two paddle plates only Alternatively use with peg set mounted and connect the defibrillator by HeartStart Defibrillator Training Cable To prevent overheating provide m...

Страница 24: ...ECG connectors as illustrated Monitoring ECG can be selected in the SimPad PLUS LLEAP ECG library The monitor defibrillator ECG lead selector can determine the ECG lead s selected Caution The ECG moni...

Страница 25: ...mPad to simulator Refer to SimPad User Guide for instructions Visit www laerdal com to download SimPad User Guide Connect to SimPad PLUS wirelessly or with a USB C cable Connect PC to simulator option...

Страница 26: ...ulator is turned off while closure valve is closed valve remains closed Closure valve will open automatically when simulator is turned on Do not use simulated vomit for suctioning To deflate stomach p...

Страница 27: ...27 Manikin will detect correct hand position Use Chest Compressions...

Страница 28: ...sure cuff measures BP manually by auscultation of Korotkoff sounds Notes Only use the Blood Pressure Cuff supplied with RA Sim BP arm can be on left or right side depending on configuration See Instal...

Страница 29: ...Notes Do not store the simulator with fluid in the IV Arm System Use a syringe to flush remains of any injected water from the tubing and components prior to storage IV arm can be on left or right sid...

Страница 30: ...stered via intramuscular injections in several sites Clean IM foam pads after each use See Cleaning section Notes Do not inject fluids into thighs Recommended use 21G or smaller sharp needles Only inj...

Страница 31: ...njection pads in manikin for extended periods of time will promote mold growth Maintenance Cleaning General Preventive maintenance is the best method to ensure optimal operation General inspection sho...

Страница 32: ...32 3 4 5 1 2 Maintenance Stomach Replacement...

Страница 33: ...33 10 6 7 9 8 Maintenance Stomach Replacement...

Страница 34: ...34 2 4 1 3 Maintenance Lung Replacement...

Страница 35: ...35 8 7 5 6 9 Maintenance Lung Replacement...

Страница 36: ...36 1 2 Maintenance Chest Rise Bladder Replacement...

Страница 37: ...37 5 3 6 4 Maintenance Chest Rise Bladder Replacement...

Страница 38: ...38 Maintenance Battery Replacement 1 2 3...

Страница 39: ...39 Maintenance Battery Replacement 6 5 7 8 9 10...

Страница 40: ...www laerdal com 20 12270 Rev C 2019 Laerdal Medical AS All rights reserved Manufacturer Laerdal Medical AS P O Box 377 Tanke Svilandsgate 30 4002 Stavanger Norway T 47 51 51 17 00 Printed in Norway...

Отзывы: