Preparing the trainer for use: 

Filling stomach reservoir: 
1.

 

Remove stomach plug from left side of 
manikin. (Photo 1) 

2.

 

Place trainer on its right side and add 20-
30cc of water through fill hole. (You may 
want to use a syringe when filling reservoir.) 

3.

 

Replace stomach plug. 

 
 
 
 
 
 
 
 
Filling the umbilical reservoir: 
1.

 

Squeeze about 3 drops of simulated blood 
concentrate into umbilical reservoir and add 
water to fill. 

2.

 

Insert umbilical tubing through skin and 
partially 

      into reservoir. (Photo 2) 
 
 

 
 
 
 
 
 
 
 
 
 
Disassembly and Reassembly: 

1.

 

Remove arms and legs by rotating counter 
clockwise. 

2.

 

Slide skin off torso. 

3.

 

Remove foam ribcage and torso foam. 

4.

 

Remove head assembly by unscrewing the 
nut on the neck. 

Photo 1 

Photo 2 

Содержание Neonatal Resuscitation Baby

Страница 1: ...Neonatal Resuscitation Baby Directions for Use...

Страница 2: ...240 00001 Laerdal 2...

Страница 3: ...001 Laerdal 3 Table of Contents Laerdal Recommends 4 Items Included 5 Skills Taught 5 Preparing the Trainer for Use 6 Disassembly and Reassembly 6 Lung Placement 7 Care and Maintenance 7 Replacement P...

Страница 4: ...is specifically designed for training professionals in the practice of neonatal intubation umbilical catheterization and umbilical IV procedures The manufacturing quality of this simulator should prov...

Страница 5: ...Baby Powder 1 Carry Case 1 Baby Pants 1 Laerdal Global Warranty Booklet Skills Taught Infant care and handling Oral and nasal intubation Oropharyngeal and Nasopharyngeal airway insertion Right mainste...

Страница 6: ...servoir 3 Replace stomach plug Filling the umbilical reservoir 1 Squeeze about 3 drops of simulated blood concentrate into umbilical reservoir and add water to fill 2 Insert umbilical tubing through s...

Страница 7: ...ns acetone iodine or other staining products and avoid placing the manikin on newsprint or inked lines of any kind 3 To ensure longevity each manikin should be cleaned after each training session and...

Страница 8: ...8 solution from pads allow them to dry then store or reinsert in manikin 5 Articulating parts will benefit from a light application of talcum powder prior to training sessions 6 Store properly between...

Страница 9: ...750 Torso Skin 240 01450 Umbilical Cord Simulated Blood Set 240 01350 Neonate Chest Foam Insert 300 00650 Manikin Lubricant 240 01050 Carry Case 240 01250 Baby Pants Cautions and Warnings This product...

Страница 10: ...240 00001 Laerdal 10 Laerdal Medical Gatesville TX All rights reserved 1004021 rev B August 30 2006...