background image

375-81001 

                                               Laerdal  

8

 

 

 
 
Care and Maintenance:

 

1.  Clean with mild soap and water; do not submerse in 

cleaning fluids or water. 

2.  Use only on clean surface. Avoid felt tipped 

markers, ink pens, acetone, iodine or other staining 
products and avoid placing the manikin on 
newsprint or inked lines of any kind.   

3.  To ensure longevity, module should be cleaned 

after each training session and a general inspection 
should be conducted regularly. 

4.   Modules and all other parts should be drained and 

air-dried thoroughly before storage and disinfected 
when needed. After use of injection pads (

use water 

only

), accumulated water should be squeezed out. 

Do not store wet foam pads in the skin. 

To 

prevent mildew or mold, pads can be soaked in a 
mild solution of disinfectant and water or bleach and 
water. Squeeze excess solution from pads, allow 
them to dry, then store or reinsert in manikin. 

5.  Articulating parts will benefit from a light application 

of talcum powder prior to training sessions. 

6.  Store properly between teaching sessions. 
 
 

 
 
 
 
 

Laerdal Recommends: 

 

This product has been designed with drain holes 
throughout arterial puncture sites. Fluid that escapes from 
punctures will collect inside arm. Opening plug at top of 
arm can drain this fluid.  
 
If using blood concentrate, flush arterial tubing with clear 
water prior to storing arm between training sessions. It is 
not necessary to remove skin and arteries after use. Wipe 
off excess moisture and allow to air dry to prevent odors. 

 

Содержание 375-81001

Страница 1: ...Arterial Stick Arm 375 81001 ASA 1000 Directions for Use ...

Страница 2: ...375 81001 Laerdal 2 ...

Страница 3: ...375 81001 Laerdal 3 Table of Contents Laerdal Recommends 4 Items Included 4 Skill Taught 4 Preparing Simulator for Use 5 Replacing Skin and Arteries 6 Care Maintenance 8 Warranty 9 Replacement Parts 10 ...

Страница 4: ... samples for monitoring blood gases As a result of quality construction and the ease of replacing individual parts this simulator should provide many sessions of training when reasonable care and maintenance are practiced Items Included 1 Arterial Stick Arm 1 Pulse Simulator Skill Taught Proper procedure for obtaining ABG Arterial Blood Gases Laerdal Recommends Arterial sticks 21 gauge needle or s...

Страница 5: ... arterial tubing 4 Allow fluid to flow through arm and out other arterial tubing 5 Place arm in horizontal position with palm up 6 Flex wrist for accurate positioning to perform radial arterial stick 7 Squeeze pulse generator for palpating a radial or brachial arterial pulse 8 Perform arterial stick Laerdal Recommends In order to prolong life of skin and tubing we recommend using a 21 gauge needle...

Страница 6: ...skin to bind Thumb will detach with skin 3 Remove tubing from track in mandrel Glue may need to be scraped away to allow removal 4 Rinse and dry grooves well and swab with alcohol Be sure to remove any excess glue 5 Place new arteries along grooves Figure 2 spot gluing as needed We recommend a fast drying glue 6 Generously lather arm mandrel with liquid soap Laerdal Recommends When excessive leaki...

Страница 7: ...375 81001 Laerdal 7 7 Slide hand into skin Photo 1 8 Work skin over fingers as with a glove Photo 2 9 Work arm skin up over mandrel Photos 3 4 Photo 1 Photo 2 Photo 3 Photo 4 ...

Страница 8: ... Do not store wet foam pads in the skin To prevent mildew or mold pads can be soaked in a mild solution of disinfectant and water or bleach and water Squeeze excess solution from pads allow them to dry then store or reinsert in manikin 5 Articulating parts will benefit from a light application of talcum powder prior to training sessions 6 Store properly between teaching sessions Laerdal Recommends...

Страница 9: ...dical is responsible for the effects of safety reliability and performance of its product s only if service repair readjustment or modification is carried out by Laerdal Medical or persons authorized by Laerdal Medical the electrical installation of the room where the product is used complies with pertinent equipment requirements the product is used in the proper manner in strict compliance with i...

Страница 10: ... the product its parts and accessories Replacement Parts Product Number Description 1000293 Pulse Simulator Assembly 1000840 Arm Drain Plug 1000191 Deltoid Pad 1000499 Artery Tubing 1000376 Arm Skin 1000711 Skin Artery Kit Please contact Customer Service Representatives for more information on Replacement Parts in other skin tones ...

Страница 11: ...375 81001 Laerdal 11 C Copyright Medical Plastics Laboratory Inc Gatesville TX Document 1001602 rev A March 28 2003 ...

Страница 12: ...4 E mail info laerdal de Italy LAERDAL ITALIA s r l Via Piero Gobetti 52 2 int Z 40129 Bologna Tel 39 051 355587 Fax 39 051 355598 E mail laerdal italia laerdal no Japan LAERDAL MEDICAL JAPAN K K Shinjuku IS Bldg 8F 2 13 12 Shinjuku Shinjuku ku Tokyo 160 0022 Tel 81 3 5919 2121 Fax 81 3 5919 2122 E mail laerdal japan laerdal co jp Malaysia LAERDAL HOSPILINE Sdn Bhd 12 Jalan Titir 33 25 Section 33 ...

Отзывы: