Instructions manual Nitrogen Compact Booster
23/38
Operation
6.4.2
Fill gas spring
1. Filling and control fitting to be prepared.
a) Small turn knob (a) to be turned left until it arrests. This moves the tripping pin (b) into
the retracted position.
b) Outlet valve (c) to be connected.
2. Remove the blanking plug above the filling opening of the gas spring with an Allen key (M6
- 3 mm; G1/8" - 5 mm).
3. Unscrew and remove set screw.
4. Filling adapter to be screwed into the filling opening of the gas spring. Tighten hand-tight.
5. Filling and control fitting to be put on the filling adapter. Screw on the large turn knob by turn-
ing it.
c
1.
b
a
xxxxx
xxxxxx
xxxxx
xxx bar
4.
5.
3.