We thank you for choosing an LAE controller. Before proceeding to the installation, please read this instructions sheet carefully; only in this way you will obtain
maximum performances and safety.

1. INSTALLATION

1.1

The SMD90 must be secured to the panel by means of screws or rivets to be inserted into the appropriate slots. Protection is IP30, therefore please locate

the unit in a position ensuring that no liquid infiltrates and damages the board.

1.2

Probes, power supply and outputs must be connected strictly according to the indications appearing on the board; the cables can pass through the hole

on the unit side. For supply voltage and maximum switchable loads, please read the label on the enclosure.
The flat cable of the SMD34RU remote unit must be connected to the relevant connector, please make sure that the mechanical polarity is respected.

1.3

The front of the SMD34RU must be inserted into the panel and sandwiched with the backside cover, then finally firmly closed by means of the screws

provided with the enclosure.

1.4

Probe T1 measures the air temperature and is used for the thermostat function. Probe T2 measures the evaporator temperature and must be secured to it

in a place where the maximum frost growth occurs.

1.5

The unit works with an ambient temperature between -10°.. +50°C and 15%.. 80% relative humidity. To reduce the effects of electro-magnetic interference,

place the probe and signal cables as away as possible from power lines.

Caution:

where delicate or valuable products have to be maintained under strict conditions, please use a different controller for limit and alarm functions.

2. OPERATING LEVELS

For 3 seconds from the power-up the display illuminates a dash (self-check phase). The following indications depend on the operating status of the controller and
from the menu level activated by the operator.
On table 1 you can see status, levels and indications relevant to them.

2.1 S

TANDBY

:

OFF permanently displayed to show the standby status. Setting the parameter 

OFF

=YES enables the [0/I] button that allows to put the SMD90

on standby. If OFF=NO the button [0/I] is inhibited.
On standby, output controls and buttons are excluded with the exception of light command (manually or door controlled).

2.2 N

ORMAL

:

during the normal operation phases, the display shows the air temperature, however the following indications can come up: ERR probe T1 fault;

ALR alarm status; DEF defrost in progress.

2.3 I

NFO MENU

:

pressing button 

enables the information selection menu. In this menu the instantaneous temperatures T1, T2 and the alarm status appear.

It’s also possible to start a defrost manually or set the setup access code. The selection of the data to be displayed can take place sequentially, by repeatedly
pressing  , or quickly via buttons 

and 

to scroll through the menu. You exit from the menu by pressing button 

or automatically after 5 seconds of no

button activation.

2.4 S

ETUP

:

you have got access to the parameter menu by selecting 47 as passcode PC. To achieve this press buttons 

and 

or  . The exit from the

setup takes place by pressing button 

or after 30 seconds of no button activation.

3. CONTROL PARAMETERS

The adaptation of the controller to the system that it controls is achieved through the parameters in the setup. The available parameters appear on table 2
hereinafter. You proceed from one parameter to the next/previous by pressing button 

or  . To display the related value, press button  , to change it press

INSTRUCTIONS FOR INSTALLATION AND USE.

SMD90B35 (A-C)

SMD34RU

S

TANDBY

N

ORMAL

I

NFO MENU

I

NFO DATA

S

ETUP

P

ARAMETER

MENU

VALUE

OFF

-20

DF

DF-

ADR

255

air temperature

manual defrost

waiting for 

peripheral 

start sequence

address

DEF

AL

A H

---

---

defrost on

alarm sources

high

….

temperature

ALR

T1

-18

---

---

new alarm

shows air 

….

temperature

ERR

T2

-22

SPH

-18

probe 1 failure

shows coil 

maximum 

temperature

setpoint

PC

47

SPL

-25

pass code 

minimum 

setting

setpoint

Table 1

Содержание SMD34RU

Страница 1: ...n table 1 you can see status levels and indications relevant to them 2 1 STANDBY OFF permanently displayed to show the standby status Setting the parameter OFF YES enables the 0 I button that allows to put the SMD90 on standby If OFF NO the button 0 I is inhibited On standby output controls and buttons are excluded with the exception of light command manually or door controlled 2 2 NORMAL during t...

Страница 2: ...ant dot on the display 5 2 In consequence to failure of probe T1 the display shows ERR and the output is controlled with a fixed time established by CDC This determines the output running time within 10 minute cycles Example CDC 06 6 minutes On 4 minutes Off 6 DEFROST 6 1 Defrost automatically starts every time the built in timer matches the time necessary to obtain the defrost frequency determine...

Страница 3: ...ill be stopped too and the alarm will be signalled 8 3 By setting parameter ACL to a value greater than 0 you enable the periodic condenser clean warning This means that when the timer counting the thermostat running time matches the weeks programmed with ACL the display will show a condenser clean request Example with ACL 16 you will obtain a warning every 16x7x24 2688 hours of compressor operati...

Страница 4: ... 041 5460713 INSTRUCTIONS FOR INSTALLATION AND USE SMD90B35E C TERMINAL FUNCTION RATINGS TERMINAL FUNCTION RATINGS L N Power supply 230 Vac 50 60Hz L3 L4 Auxiliary loads 8 3 A 230 Vac L1 L2 Compressor 20 6 A 230 Vac L9 L10 Defrost 8 3 A 230 Vac L5 L6 Evap Fans 8 3 A 230 Vac A1 A2 Alarm 8 3 A 230 Vac A3 L7 Indoor lights 8 3 A 230 Vac WIRING DIAGRAM ...