WIRING DIAGRAM

VIA PADOVA, 25
31046 ODERZO /TV /ITALY
TEL. 0422 815320 - 815303
TELEFAX 0422 814073
www.lae-electronic.com
E-mail: [email protected]

PA

RTNER VENEZIA • 041 5460713

INSTRUCTIONS FOR INSTALLATION AND USE.

SETUP

1

SPL

-50 ... 150

-30

2

SPh

SPL ... 150

20

3

hyS

01 ... 20

02

4

coF

00 ... 10

00

5

con

00 ... 10

00

6

cdc

00 ... 10

05

7

crS

00 ... 120

00

8

drE

01 …. 99 

06

9

dLi

01 ... 70

10

10

dto

01 ... 120

30

11

drP

00 ... 10

03

12

diS

-01 ... 30 

10

13

dty

FAn;  ELE;  GAS

ELE

14

doP

con; Acc

con

15

Fct

-01;  00... 10 

01

16

FrS

-50 ... 150

-10

17

Fid

00;  01; 02

00

18

Alo

-50 ... 150

-32

19

Ahi

Alo ... 150

22

20

AdL

-01; 00... 120

10

21

Ain

1; 2; 3

01

22

oS1

-20 ... 20

00

23

oS2

-20 ... 20

00

24

oS3

-20 ... 20

00

25

SiM

00 ... 200

00

26

Adr

00 ... 255

01

CDC122T1R3B

CDC122T1R3J - CDC122T1R3G

Содержание CDC122T1R2

Страница 1: ... about the relay contact life Where delicate or valuable products have to be maintained under strict conditions please use a different controller for limit and alarm functions 2 CONTROL PARAMETERS The adaptation of the CDC 12 to the system that it controls is achieved through the parameters in the SETUP Access to the parameters is obtained by pressing for 4 seconds Scroll through the parameters by...

Страница 2: ...e cooler run isn t controlled according to setpoint but determined by cdc which represents the cooler duty cycle i e on time 10 minute cycle For ex 04 4 minutes on time 6 minutes off time The cdc value has to be set taking into consideration the normal cooler duty cycle If you wish to switch off the outputs you can put the CDC12 on a standby via the serial communication or manually by pressing dur...

Страница 3: ...s case the condition must be acknowledged by pressing any key The alarm output contact is also closed when the instrument is powerless During defrost and dripping the high alarm monitoring is inhibited 9 PROBE RE CALIBRATION Should it be necessary to recalibrate the unit for instance in consequence of probe replacement then act in the following way get an accurate reference thermometer or calibrat...

Страница 4: ...150 20 3 hyS 01 20 02 4 coF 00 10 00 5 con 00 10 00 6 cdc 00 10 05 7 crS 00 120 00 8 drE 01 99 06 9 dLi 01 70 10 10 dto 01 120 30 11 drP 00 10 03 12 diS 01 30 10 13 dty FAn ELE GAS ELE 14 doP con Acc con 15 Fct 01 00 10 01 16 FrS 50 150 10 17 Fid 00 01 02 00 18 Alo 50 150 32 19 Ahi Alo 150 22 20 AdL 01 00 120 10 21 Ain 1 2 3 01 22 oS1 20 20 00 23 oS2 20 20 00 24 oS3 20 20 00 25 SiM 00 200 00 26 Ad...

Отзывы: