INSTRUCTIONS OF USE
19
3.
Secondary-air intake
By opening this inlet, air enters the
firebox via the top of the firebox door.
IMPORTANT
: Keeping the secondary-air
intake open helps keep the door glass
cleaner for longer.
Double-combustion air intake
By opening this inlet, air enters the
combustion flame, making for more
efficient and less polluting combustion
because post-combustion takes place,
burning the particles which were not
burned in the first combustion. This
increases the performance of the appliance
and reduces emissions.
In order to obtain maximum output,
open all the air intakes to the firebox and
in order to obtain minimum output, tend
towards closing them. For normal use, we
recommend Secondary Intakes open.
IMPORTANT:
The appliance is exposed to
extreme changes in temperature and may,
as a result, make noises when in operation.
These noises are a natural result of
expansion/contraction of the parts which
make up the appliance. Do not be alarmed
by noises of this kind.
In order to obtain maximum output,
open all the air intakes to the firebox and
in order to obtain minimum output, tend
towards closing them. For normal use, we
recommend you close the Primary Intake
and leave the Secondary Combustion
Intakes open.
3.7.
Removing ash
Following
sustained
use
of
the
appliance, it is necessary to remove the ash
from the firebox. Remove the ashpit box
when cold or using something to prevent
yourself from getting burned (glove).
Never throw hot embers into the
rubbish.
Access the ashpit by opening the door
on the appliance.
Figure No.15 -
Extract ashpit
Warning!
It is very important to put the
ashpit back in its housing at the bottom of
the firebox after emptying it of ashes and
before lighting the fire again! Do this by
following the extraction process in reverse
order.
3.8.
Deflector.
The appliance has 2 deflectors.
Содержание Titanium 700 Plus
Страница 1: ...Titanium Plus Instruction Book ...
Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Titanium 701 Plus appliance in mm ...
Страница 7: ...PRESENTATION OF THE APPLIANCE 6 1 Figure No 3 Dimensions of the Titanium 702 Plus appliance in mm ...
Страница 8: ...PRESENTATION OF THE APPLIANCE 7 1 Figure No 4 Dimensions of the Titanium 703 Plus appliance in mm ...
Страница 26: ...BASIC BREAKDOWNS 25 6 BASIC BREAKDOWNS ...
Страница 27: ...BASIC BREAKDOWNS 26 6 ...
Страница 28: ...BASIC BREAKDOWNS 27 6 ...
Страница 29: ...DECLARATION OF PERFORMANCE 28 7 DECLARATION OF PERFORMANCE ...
Страница 30: ...DECLARATION OF PERFORMANCE 29 7 ...
Страница 31: ...CE MARK 30 8 CE MARK ...