INSTRUCTIONS OF USE 

15 

 

 

3.  

3.3.

 

Lighting 

Use  of  the  appliance  in  warm  weather 

(warm  days,  early  hours  of  the  afternoon 
on  sunny  days)  may  lead  to  lighting  and 
updraught problems. 

Certain weather conditions, such as fog, 

ice,  humidity  entering  the  flue,  etc.,  may 
hinder sufficient updraught in the flue and 
lead to suffocation. 

Proceed as follows in order to light  the 

appliance satisfactorily: 

 

Open the firebox door(s) and open 

all  the  firebox  air-intake  inlets  to  the 
full. 

 

Place  paper  or  a  firelighter  and 

some wood chips in the firebox.  

 

Light the paper or firelighter. 

 

Leave  the  door  slightly  ajar,  the 

width of two or three fingers, for about 
15 minutes until the glass warms up. 

 

The  first  time  the  appliance  is  lit, 

the  fire  should  be  gentle  to  allow  the 
parts of the appliance to dilate and dry. 

 

Important:

 The first time it is lit up, the 

appliance  may  give  off  smoke  and  strange 
smells.  This  is  not  a  cause  for  concern. 
Open  an  outdoor  window  to  ventilate  the 
room  during  the  first  few  hours  of 
operation. 

If  you  notice  water  around  the 

appliance,  this  is  produced  by  the 
condensation of the moisture in the  wood 
on  lighting  the  fire.  This  condensation  will 
no  longer  appear  when  the  appliance  has 
been  lit  three  or  four  times  and  has 
adapted to its flue. If it does not disappear, 
then  check  the  flue  draught  (length  and 
diameter  of  the  flue,  flue  insulation, 
airtightness) and the humidity of the wood 
used. 

3.4.

 

Loading fuel 

In  order  to  load  firewood,  open  the 

firebox door gently, preventing the sudden 
entry  of  air  to  the  firebox  so  that  smoke 
does not enter the room that the appliance 
is installed in.  

Perform this operation with the glove to 

prevent burns to the hands.  

Always  load  with  medium  primary  air 

settings (see table in section 1.1). 

For minimum burning (e.g. at night), use 

thicker logs. 

When  the  firebox  is  loaded,  close  the 

door. 

Be careful when placing logs in the firebox 

on appliances with vermiculite interiors. 
Vermiculite is a fragile material and may 

crack if knocked. 

3.5.

 

Operation 

The  appliance  should  be  operated  with 

the doors closed. 

For safety reasons, never close all the 

appliance’s combustion

-air intakes. 

Air intake 

By  opening  this  inlet,  air  enters  the 

firebox in the following sequential way: 

1º-  Through  the  double  combustion 

holes  on  the  sides  of  the  combustion 
chamber. 

2º-  At  the  top  of  the  combustion 

chamber door. 

3º-  Finally,  air  is  introduced  into  the 

combustion chamber through the grille. 

IMPORTANT

: Keeping the secondary-air 

intake open (the air that enters the firebox 

via the top of the firebox door) helps keep 

the door glass cleaner for longer. 

 

Содержание Nickel AUSTRALIA

Страница 1: ...Nickel Instruction Book AUSTRALIA ...

Страница 2: ...ng to installers 6 2 2 Room for installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 8 2 3 3 Checks before lighting for the first time 8 2 3 4 Height adjustment and levelling the appliance 8 2 3 5 Casing 8 2 3 6 Connection to the flue 10 2 3 7 Piping air to the firebox 10 2 3 8 Exterior...

Страница 3: ...ance 18 4 1 3 Flue socket 18 4 1 4 Painted sheet steel cast iron parts 18 4 1 5 Firebox glass 18 4 1 6 Air intake registers 18 4 2 Maintenance of the chimney flue 19 4 3 Important advice 19 TROUBLESHOOTING 20 BASIC BREAKDOWNS 21 CERTIFICATE OF COMPLIANCE 23 ...

Страница 4: ...RALL AVERAGE EFFICIENCY BURNING HARDWOOD 64 60 PARTICULATE EMISSIONS FACTOR g kg 0 9 0 9 HIGH BURN Average power high primary air settings kW 9 9 15 6 Average Peak Power kW 15 8 19 9 Efficiency high primary air settings 57 54 Average dry fuel consumption rate high primary air settings Kg hr 3 2 5 Particulate emission factor oven dry wood high primary air settings g kg 0 8 0 7 MEDIUM BURN Average p...

Страница 5: ... of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warrant To obtain these data tests have been done on the standards AS NZS 4012 2014 AS NZS 4013 2014 and AS NZS 2918 2018 with eucalyptus wood Figure No 1 Dimensions of the Nickel 800 appliance in ...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Nickel 1000 appliance in mm ...

Страница 7: ...f the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at less than 30 cm from the c...

Страница 8: ... wide x 36mm thick floor protector compressed board should be used in front of each of the appliance doors and be placed centrally in the 1110mm width The Thermal resistivity of the 50mm skamol board floor protector is 0 74m K W The Thermal resistivity of the floor protector is 0 16m K W for 36mm thick compressed board sheets Minimum air gap of 40mm must be maintained under the appliance base to t...

Страница 9: ...he deflectors are correctly positioned Make sure that the airtight joints on the flue circuit are in perfect condition Make sure that the doors close properly Make sure that all moving parts are fitted in place 2 3 4 Height adjustment and levelling the appliance The appliance must be perfectly level horizontally and vertically both at the front and on the sides use a spirit level The appliance has...

Страница 10: ...on chosen with or without forced ventilation combustion air from indoors or outdoors directed hot air outlets with or without pipes etc A further hot air ventilation grille is also recommended between the insulating deflector on the hood and the ceiling As well as this the hood closure should have a free opening of at least 100 cm2 for the intake of air for combustion Warning on appliances on whic...

Страница 11: ... bottom front of the appliance If the tube is straight it can have a maximum of 12 meters in length If you use accessories like elbows you must subtract the total length 12 meters 1 meter for each accessory used This is the best option because it means that draughts are not created in and oxygen is not consumed from the room in which the appliance is fitted A further advantage is that there is no ...

Страница 12: ...nd airtight over its entire length The flue must be at least 5m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downdraught cowl a static cowl or a smoke extraction fan or reshape the chimney Never make 90º bends due to the great loss of draught they cause and reduce 45º bends down to an a...

Страница 13: ...between chimney crown and roof ridge The chimney crown must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 14 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet...

Страница 14: ...stored The logs should have a maximum diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech hardwood and eucalyptus logs Other fuels Oak chestnut ash maple birch elm etc Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All types of coal and liquid fuel Green wood Green or damp wood ...

Страница 15: ...TIONS OF USE 14 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 17 Operating components on the appliance A Firebox door handle B Air intake o B1 closed left o B2 open right ...

Страница 16: ...ance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Loading fuel In order to load firewood open the firebox door gently preventing the sudden entry of air to the firebox so that smoke does not enter the room that the appliance is inst...

Страница 17: ... operated with all combustion rate controls adjusted to the minimum setting c Medium burn rate The appliance shall be operated with the register in the middle of its position Lacunza recommends doing medium burn cycles 3 6 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to prevent yourself f...

Страница 18: ...Figure No 20 Remove the refractories from the right side Figure No 21 Turn the right side refractory as in the picture so that the deflector can fall Figure No 22 Drop the refractory holding it Figure No 23 Remove de deflector ...

Страница 19: ...should be kept open However over the hours of use the glass may become dirty To clean it we will use specific degreasing products or dry cleaning products for this task The cleaning should be carried out with the glass cold and taking care not to apply the glass cleaner directly on the glass as if it comes into contact with the door s closing cord it may deteriorate Put the cleaning product on the...

Страница 20: ...ire in the chimney close the flue draught close doors and windows remove embers from the firebox block the connection hole with damp cloths and call the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability for any modification to the product which it has not authorised This appliance is a heat producing appliance a...

Страница 21: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 22: ...nilla puerta hogar 2 7 Cordón plano pelos 8x2mm 2 5 m 8 509020000042 Cordón Negro Ø13mm 2 5 m 9 5044700009 Nickel DC Vermiculita Lateral 340x340x60 mm 2 10 5044700010 Nickel 700 DC Vermiculita Base lateral 210x149x30 mm 4 5044800007 Nickel 800 DC Vermiculita Base lateral 210x199x30 mm 4 5045300007 Nickel 1000 DC Vermiculita Base Lateral 48x329x30 4 13 5044700007 Nickel 700 DC Deflector vermiculita...

Страница 23: ...BASIC BREAKDOWNS 22 6 5045300005 Cjto marco de 50 Silver 1000 For Nickel 1000 South Africa and Australia 2 ...

Страница 24: ...CERTIFICATE OF COMPLIANCE 23 7 CERTIFICATE OF COMPLIANCE ...

Страница 25: ...CERTIFICATE OF COMPLIANCE 24 7 ...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea 5A 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: