background image

 

 

PRESENTATION OF THE APPLIANCE 

 

 

1.  

Warning:

 this appliance is designed and prepared to work with the types of fuel, degree of 

humidity of the fuel, fuel loads, fuel load frequencies, flue draught and system of installation 

indicated in this Instruction Book. Failure to respect these conditions may lead to problems 

with the appliance (deterioration, shorter useful life, etc.) which are not covered by the 

Lacunza warranty. 

 

 

Figure No.1 -

 

Dimensions of the Nickel 800 DC appliance in mm 

 

Содержание Nickel 800 DC

Страница 1: ...Nickel 800 DC Nickel 1000 DC Instruction Book...

Страница 2: ...ng to installers 6 2 2 Room for installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7...

Страница 3: ...4 1 3 Flue socket 18 4 1 4 Painted sheet steel cast iron parts 18 4 1 5 Firebox glass 18 4 1 6 Air intake registers 18 4 2 Maintenance of the chimney flue 18 4 3 Important advice 18 TROUBLESHOOTING 1...

Страница 4: ...ch country and this instruction book 1 1 General characteristics Unit Nickel 800 DC Nickel 1000 DC Nominal Heat Output N H O to atmosphere kW 15 16 Efficiency at N H O 80 75 CO emission at 13 O2 at N...

Страница 5: ...he fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterior...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Nickel 1000 DC appliance in mm...

Страница 7: ...the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for inta...

Страница 8: ...combustible material 2 3 2 Safety distances Be sure to respect the appliance installation distances from combustible materials Looking at the appliance head on Distance to combustible materials mm Fro...

Страница 9: ...ts height The legs can be adjusted using a 24mm spanner 2 3 5 Casing Make sure that the material around the appliance is not flammable or likely to deteriorate as a result of heat wallpaper carpet pla...

Страница 10: ...ure should have a free opening of at least 100 cm2 for the intake of air for combustion Warning on appliances on which it is possible to pipe air to the firebox the hood requires a further air inlet a...

Страница 11: ...meter for each accessory used This is the best option because it means that draughts are not created in and oxygen is not consumed from the room in which the appliance is fitted A further advantage i...

Страница 12: ...length The flue must be at least 6m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downd...

Страница 13: ...acle located within a 10m radius of the chimney outlet by more than 1m Figure No 12 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring bu...

Страница 14: ...ly chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very...

Страница 15: ...IONS OF USE 14 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 15 Operating components on the appliance A Firebox door handle B Air intake o B1 closed left o B2 op...

Страница 16: ...liance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity o...

Страница 17: ...end you the air Intake 50 open 3 6 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to preven...

Страница 18: ...ure No 19 Remove the four refractories from the right side Figure No 20 Turn the right side refractory as in the picture so that the deflector can fall Figure No 21 Drop the refractory holding it Figu...

Страница 19: ...glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold...

Страница 20: ...continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Control...

Страница 21: ...40000904 Nickel Adour Parrilla hogar 1 6 5044700002 Nickel Manilla puerta hogar 2 7 Cord n plano pelos 8x2mm 2 5 m 8 509020000042 Cord n Negro 13mm 2 5 m 9 5044700003 Nickel DC Vermiculita Lateral 340...

Страница 22: ...DECLARATION OF PERFORMANCE 21 7 DECLARATION OF PERFORMANCE...

Страница 23: ...DECLARATION OF PERFORMANCE 22 7...

Страница 24: ...CE MARK 23 8 CE MARK...

Страница 25: ...CE MARK 24 8...

Страница 26: ......

Страница 27: ......

Страница 28: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0...