Lacunza LEVANTE Скачать руководство пользователя страница 3

 

 

PRESENTATION OF THE APPLIANCE 

 

 

1.  

4.1.2. Inside the appliance ............................................................................................................................................... 15

 

4.1.3. Flue socket ............................................................................................................................................................. 15

 

4.1.4. Chrome parts.......................................................................................................................................................... 15

 

4.1.5. Painted sheet-steel-cast-iron parts. ....................................................................................................................... 15

 

4.1.6. Brass parts .............................................................................................................................................................. 15

 

4.1.7. Firebox glass ........................................................................................................................................................... 15

 

4.2. Maintenance of the chimney flue .............................................................................................................. 15

 

4.3. Important advice ........................................................................................................................................ 15

 

 TROUBLESHOOTING .......................................................................................................................... 17

 

 BASIC BREAKDOWNS ........................................................................................................................ 18

 

 DECLARATION OF PERFORMANCE .................................................................................................... 20

 

 CE MARK ........................................................................................................................................... 22

 

Содержание LEVANTE

Страница 1: ...LEVANTE Instruction Book ...

Страница 2: ...LLER 5 2 1 Warning to installers 5 2 2 Room for installation 5 2 2 1 Ventilation of the room 5 2 2 2 Location of the appliance in the room 6 2 3 Installation of the appliance 6 2 3 1 Floor 6 2 3 2 Safety distances 6 2 3 3 Checks before lighting for the first time 6 2 3 4 Height adjustment and levelling the appliance 6 2 3 5 Connection to the flue 6 2 3 5 1 Rear flue socket 7 2 3 5 2 Top flue socke...

Страница 3: ...3 Flue socket 15 4 1 4 Chrome parts 15 4 1 5 Painted sheet steel cast iron parts 15 4 1 6 Brass parts 15 4 1 7 Firebox glass 15 4 2 Maintenance of the chimney flue 15 4 3 Important advice 15 TROUBLESHOOTING 17 BASIC BREAKDOWNS 18 DECLARATION OF PERFORMANCE 20 CE MARK 22 ...

Страница 4: ...ce with the specifications set out in the legislation applicable in each country and this instruction book 1 1 General characteristics Unit Levante Nominal Heat Output N H O to atmosphere kW 11 Efficiency at N H O 74 CO emission at 13 O2 at N H O 0 27 Gas mass flow at N H O g s 9 1 Gas temperature of flue at N H O ºC 400 Optimum flue draught Pa 12 Wood consumption beech at N H O Kg h 3 2 Dimension...

Страница 5: ...of the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty Figure No 1 Dimensions of the Levante appliance in mm ...

Страница 6: ...solutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated ...

Страница 7: ...hting for the first time Make sure that the glass es is are not broken or damaged Make sure that the flueway is not obstructed with packing or loose parts Make sure that the airtight joints on the flue circuit are in perfect condition Make sure that the doors close properly Make sure that all moving parts are fitted in place 2 3 4 Height adjustment and levelling the appliance The appliance must be...

Страница 8: ...iping can be used inside the building the heat of the gases serving to heat rooms insulating only those sections where excess temperature may cause damage If the chimney is constructed then it is necessary to pipe and insulate it to ensure correct updraught The diameter of the pipe must be the same as the diameter of the flue socket on the appliance over its entire length in order to ensure correc...

Страница 9: ...ustible material in order to prevent breakage deformation etc as a result of overheating if the material is not designed to withstand high temperatures It must be possible to clean the entire flue no sections being left inaccessible for cleaning purposes 2 4 2 Chimney crown The upper end of the chimney must clear the roof the roof ridge or any obstacle located on the roof by at least 1m Figure No ...

Страница 10: ...himney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 7 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Страница 11: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Страница 12: ...INSTRUCTIONS OF USE 11 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 9 Operating components on the appliance ...

Страница 13: ...ht in the flue and lead to suffocation Proceed as follows in order to light the appliance satisfactorily Open the firebox door s and open all the firebox air intake inlets to the full Place paper or a firelighter and some wood chips in the firebox Light the paper or firelighter Leave the door slightly ajar the width of two or three fingers for about 15 minutes until the glass warms up The first ti...

Страница 14: ...r intake By opening this inlet air enters the firebox via the firebox grille Secondary air intake By opening this inlet air enters the firebox via the top of the firebox door IMPORTANT Keeping the secondary air intake open helps keep the door glass cleaner for longer Double combustion air intake By opening this inlet air enters the combustion flame making for more efficient and less polluting comb...

Страница 15: ... Figure No 11 Remove the top cover of the stove Unscrew and remove the 4 screws that hold the second sheet metal cover A Remove the deflector lifting it first at the front and then at the rear B and C Figure No 11 Removing the deflector Soot falling from the flue may build up on the deflector ...

Страница 16: ...ning the glass the liquids used must not dampen the painted steel 4 1 6 Brass parts Use special brass cleaning products available on the market to clean the brass parts 4 1 7 Firebox glass Keep the secondary air intake open to keep the door glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used t...

Страница 17: ...lity for any modification to the product which it has not authorised This appliance is a heat producing appliance and contact may lead to burns This appliance may remain HOT for a period of time after it has gone out MAKE SURE THAT SMALL CHILDREN DO NOT GO NEAR IT ...

Страница 18: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 19: ...BASIC BREAKDOWNS 18 6 BASIC BREAKDOWNS ...

Страница 20: ...000043 6 Manilla puerta cenicero de Cromo France 502050000028 7 Cordón puerta hogar cenicero lateral Ø8mm 500900000010 8 Cordón plano entre cristal y puerta 8x2mm 500000000510 9 Tirador registro primario 504020000046 10 Piedra refractaria 220x110x30 502050000014 11 Levante Lujo piedra refractaria pequeña 220x33x30 500000000086 12 Tubo doble combustión 502050000039 13 Deflector 502050000003 14 Ganc...

Страница 21: ...DECLARATION OF PERFORMANCE 20 7 DECLARATION OF PERFORMANCE ...

Страница 22: ...DECLARATION OF PERFORMANCE 21 7 ...

Страница 23: ...CE MARK 22 8 CE MARK ...

Страница 24: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: