BASIC BREAKDOWNS 

29 

 

 

6.  

 

BASIC BREAKDOWNS  

 

Figure No.40 -

 

Itaca 80 Basic breakdowns 

Nº 

Código  

Denominación 

Cant. 

504120000033 

Marco exterior Itaca 80  

504120000034 

Cristal puerta 702x482Itaca 80 

504000000068 

Cordón cerámico 15x10mm puerta Itaca 80  

504000000058 

Parrilla base hogar Itaca 80-100-120 

504000000857 

Cjto. sist. cierre puerta DCHA Itaca 80-100-120 

504000000858 

Cjto. sist. cierre puerta IZQDA Itaca 80-100-120 

5041200036 

Deflector inferior ITACA 80 

504120000003 

Deflector medio y superior ITACA 80 

 

 

 

 

 

 

 

 

Содержание ITACA Series

Страница 1: ...Itaca 80 100 120 C V Instruction Book...

Страница 2: ...ation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7 2 3 3 Checks before lighting for the fi...

Страница 3: ...lotine system 23 3 8 2 Door opening system to clean the glass 24 3 9 Electrical system 26 MAINTENANCE AND IMPORTANT ADVICE 27 4 1 Maintenance of the appliance 27 4 1 1 Firebox 27 4 1 2 Inside the appl...

Страница 4: ...it ITACA 80 ITACA 100 ITACA 120 Nominal Heat Output N H O to atmosphere kW 12 17 16 5 Efficiency at N H O 85 78 81 CO emission at 13 O2 at N H O 0 08 0 19 0 28 Gas mass flow at N H O g s 9 1 10 14 Gas...

Страница 5: ...f the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deter...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Itaca 100 appliance in mm Figure No 3 Dimensions of the Itaca 120 appliance in mm...

Страница 7: ...the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for inta...

Страница 8: ...f the non combustible material is not designed to withstand high temperatures 2 3 3 Checks before lighting for the first time Make sure that the glass es is are not broken or damaged Make sure that th...

Страница 9: ...he appliance check that the guillotine door works properly the door rises and lowers smoothly and without any friction or noise other than that of correct operation of the guillotine system 2 3 5 Casi...

Страница 10: ...he installer must fit the necessary inspection accesses trap doors hatches etc so that everything inside the hood that may need maintenance work or replacement can be accessed at any time e g counterw...

Страница 11: ...ance for combustion straight from outdoors We recommend that if possible air be drawn from outdoors for combustion via a non closable pipe with a diameter of 120mm leading to the nozzle on the bottom...

Страница 12: ...om the hot air output nozzles on the appliance to the hot air output grilles on the casing or to other rooms The air flow required at any given time can also be regulated via the potentiometer on the...

Страница 13: ...to excess temperature The combustion air intake through the 120mm diameter nozzle on the front bottom of the appliance which can be piped in from outdoors MUST be fully independent from the fan air i...

Страница 14: ...g the frame Perform the removal process in reverse order to refit the frame 2 3 10 Fan potentiometer connection only for models C V ITACA c v models the models with fans are prepared for connection on...

Страница 15: ...have its own chimney flue never sharing a chimney flue with another appliance 2 4 1 Type of flue The flue must be made of special material designed to resist the products of combustion e g stainless s...

Страница 16: ...stible material in order to prevent breakage deformation etc as a result of overheating if the material is not designed to withstand high temperatures It must be possible to clean the entire flue no s...

Страница 17: ...himney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 19 Distances bet...

Страница 18: ...ly chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very...

Страница 19: ...Secondary air intake o C1 open move towards the symbol o C2 closed move towards the symbol D LEFT HAND catch on the door opening system to clean the glass o D1 open turn anti clockwise o D2 closed tu...

Страница 20: ...re in the wood on lighting the fire This condensation will no longer appear when the appliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue...

Страница 21: ...not be alarmed by noises of this kind In order to obtain maximum output open all the air intakes to the firebox and in order to obtain minimum output tend towards closing them If you wish the fire to...

Страница 22: ...eater retention and therefore greater efficiency Position 4 more open to be used when there are smoke downdraught problems caused by insufficient updraught You can see how they are fitted and regulate...

Страница 23: ...r on the Itaca Soot falling from the flue may build up on the deflector Then remove the second deflector by drawing it forwards and allowing it to drop at the rear Figure No 27 Removing the upper defl...

Страница 24: ...is system in which the door opens vertically is the usual way to open and close the firebox in order to load and rearrange the firewood when the appliance is in normal use Use the glove supplied in or...

Страница 25: ...32 Turn the catch anti clockwise Remove the tool from the left hand catch and use it to perform the same operation on the right hand catch inserting it in the same way Then turn the catch clockwise as...

Страница 26: ...o as not to damage the enamel or paint NOTE When you have cleaned the door glass and want to return it to guillotine opening mode perform the same process in reverse order When you turn the catches at...

Страница 27: ...from the appliance in two ways Automatic mode The fan automatically starts working at the set speed via the thermostat When a fire has been lit in the firebox and the thermostat reaches a temperature...

Страница 28: ...s Keep the secondary air intake open to keep the door glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose sho...

Страница 29: ...mes up too much Excessive primary air Close the primary and secondary air intakes partially or totally Excessive updraught Install a draught damper Smoke given off on lighting Poor quality wood Do not...

Страница 30: ...stal puerta 702x482Itaca 80 1 3 504000000068 Cord n cer mico 15x10mm puerta Itaca 80 1 4 504000000058 Parrilla base hogar Itaca 80 100 120 1 5 504000000857 Cjto sist cierre puerta DCHA Itaca 80 100 12...

Страница 31: ...1 3 504000000068 Cord n cer mico 15x10mm puerta Itaca 100 1 504000000068 Cord n cer mico 15x10mm puerta Itaca 120 1 4 504000000058 Parrilla base hogar Itaca 80 100 120 1 5 504000000857 Cjto sist cier...

Страница 32: ...BASIC BREAKDOWNS 31 6...

Страница 33: ...BASIC BREAKDOWNS 32 6...

Страница 34: ...BASIC BREAKDOWNS 33 6...

Страница 35: ...DECLARATION OF PERFORMANCE 34 7 DECLARATION OF PERFORMANCE...

Страница 36: ...DECLARATION OF PERFORMANCE 35 7...

Страница 37: ...DECLARATION OF PERFORMANCE 36 7...

Страница 38: ...DECLARATION OF PERFORMANCE 37 7...

Страница 39: ...DECLARATION OF PERFORMANCE 38 7...

Страница 40: ...DECLARATION OF PERFORMANCE 39 7...

Страница 41: ...CE MARK 40 8 CE MARK...

Страница 42: ...CE MARK 41 8...

Страница 43: ...CE MARK 42 8...

Страница 44: ...CE MARK 43 8 LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 01...

Отзывы: