background image

 

 

BASIC BREAKDOWNS 

21 

 

 

6.  

 

BASIC BREAKDOWNS  

 

Figure No.20 -

 

Verona 1000-1001-1003 Basic breakdowns 

Nº 

CÓDIGO 

DENOMINACION 

CANTIDAD 

5044700000 

Nickel DC Maneta registro entrada aire 

5044700001 

Nickel DC Cenicero doble 

5044700008 

Nickel 700 DC Separador 

5044800000 

Nickel 800 DC Separador 

5045300001 

Nickel 1000 DC Separador 

5044700002 

Nickel 700 DC Cristal puerta hogar + junta 

5044800001 

Nickel 800 DC Cristal puerta hogar + junta 

5045300000 

Nickel 1000 DC Cristal puerta hogar 

5040000897 

Sylver 800 plus, Parrilla fundición 

5044700002 

Nickel Manilla puerta hogar 

 

Cordón plano pelos 8x2mm 

2,5 m 

509020000042 

Cordón Negro Ø13mm 

2,5 m 

5044700009 

Nickel DC Vermiculita Lateral 340x340x60 mm 

10 

5044700010 

Nickel 700  DC Vermiculita Base lateral 210x149x30 mm 

5044800007 

Nickel 800 DC Vermiculita Base lateral 210x199x30 mm 

5045300007 

Nickel 1000 DC, Vermiculita Base Lateral 48x329x30  

11 

5044700007 

Nickel 700 DC Deflector vermiculita  

5044800004 

Nickel 800 DC Deflector vermiculita  

5045300004 

Nickel 1000 DC Deflector vermiculita 

 

Содержание AUSTRALIA Verona 1000

Страница 1: ...Instruction Book AUSTRALIA Verona 1000 Verona 1001 Verona 1003 ...

Страница 2: ...7 2 2 Room for installation 7 2 2 1 Ventilation of the room 7 2 2 2 Location of the appliance in the room 8 2 3 Installation of the appliance 8 2 3 1 Floor 8 2 3 2 Safety distances 8 2 3 3 Checks before lighting for the first time 8 2 3 4 Height adjustment and levelling the appliance 9 2 3 5 Connection to the flue 9 2 3 6 Piping air to the firebox 9 2 4 Chimney flue 10 2 4 1 Type of flue 10 2 4 2 ...

Страница 3: ...TION OF THE APPLIANCE 2 1 4 1 5 Firebox glass 18 4 1 6 Air intake registers 18 4 2 Maintenance of the chimney flue 19 4 3 Important advice 19 TROUBLESHOOTING 20 BASIC BREAKDOWNS 21 CERTIFICATE OF COMPLIANCE 22 ...

Страница 4: ...G HARDWOOD 60 60 60 PARTICULATE EMISSIONS FACTOR g kg 0 9 0 9 0 9 HIGH BURN Average power high primary air settings kW 15 6 15 6 15 6 Average Peak Power kW 19 9 19 9 19 9 Efficiency high primary air settings 54 54 54 Average dry fuel consumption rate high primary air settings Kg hr 5 5 5 Particulate emission factor oven dry wood high primary air settings g kg 0 7 0 7 0 7 MEDIUM BURN Average power ...

Страница 5: ...of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty To obtain these data tests have been done on the standards AS NZS 4012 2014 AS NZS 4013 2014 and AS NZS 2918 2018 with eucalyptus wood Figure No 1 Dimensions of the Verona 1000 appliance in...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Verona 1001 appliance in mm ...

Страница 7: ...PRESENTATION OF THE APPLIANCE 6 1 Figure No 3 Dimensions of the Verona 1003 appliance in mm ...

Страница 8: ...f the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at less than 30 cm from the c...

Страница 9: ...t AS NZS 2918 2018 3 3 2 A minimum 600mm deep x 1320mm wide x 36mm thick floor protector compressed board should be used in front of each of the appliance doors and be placed centrally in the 1320mm width The Thermal resistivity of the 50mm skamol board floor protector is 0 74m K W The Thermal resistivity of the floor protector is 0 16m K W for 36mm thick compressed board sheets Minimum air gap of...

Страница 10: ...ected to the appliance is well secured and there is no chance of it coming free from its housing e g as a result of dilatation due to temperature etc 2 3 6 Piping air to the firebox On this model it is possible to pipe air to the appliance for combustion straight from outdoors We recommend that if possible air be drawn from outdoors for combustion via a non closable pipe with a diameter of 120mm l...

Страница 11: ...gth in order to ensure correct operation The flue must prevent the entry of rainwater The flue must be clean and airtight over its entire length The flue must be at least 5m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downdraught cowl a static cowl or a smoke extraction fan or reshape ...

Страница 12: ...end of the chimney must clear the roof the roof ridge or any obstacle located on the roof by at least 1m Figure No 9 Distances between chimney crown and roof ridge The chimney crown must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 10 Distances between the chimney crown and objects within a 10m radius T...

Страница 13: ...INSTRUCTIONS FOR THE INSTALLER 12 2 Figure No 11 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Страница 14: ...stored The logs should have a maximum diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech hardwood and eucalyptus logs Other fuels Oak chestnut ash maple birch elm etc Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All types of coal and liquid fuel Green wood Green or damp wood ...

Страница 15: ...TIONS OF USE 14 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 13 Operating components on the appliance A Firebox door handle B Air intake o B1 closed left o B2 open right ...

Страница 16: ...e has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Loading fuel In order to load firewood open the firebox door gently preventing the sudden entry of air to the firebox so that smoke does not enter the room that the appliance is install...

Страница 17: ...iance shall be operated with all combustion rate controls adjusted to the minimum setting c Medium burn rate The appliance shall be operated with the register in the middle of its position Lacunza recommends doing medium burn cycles 3 6 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to prev...

Страница 18: ... Figure No 16 Remove the refractory from the right side Figure No 17 Turn the right side refractory as in the picture so that the deflector can fall Figure No 18 Drop the refractory holding it Figure No 19 Remove de deflector ...

Страница 19: ...should be kept open However over the hours of use the glass may become dirty To clean it we will use specific degreasing products or dry cleaning products for this task The cleaning should be carried out with the glass cold and taking care not to apply the glass cleaner directly on the glass as if it comes into contact with the door s closing cord it may deteriorate Put the cleaning product on the...

Страница 20: ...ire in the chimney close the flue draught close doors and windows remove embers from the firebox block the connection hole with damp cloths and call the fire brigade 4 3 Important advice Lacunza recommends that only Lacunza authorised replacement parts be used Lacunza accepts no liability for any modification to the product which it has not authorised This appliance is a heat producing appliance a...

Страница 21: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 22: ...r junta 2 5045300000 Nickel 1000 DC Cristal puerta hogar 2 5 5040000897 Sylver 800 plus Parrilla fundición 1 6 5044700002 Nickel Manilla puerta hogar 2 7 Cordón plano pelos 8x2mm 2 5 m 8 509020000042 Cordón Negro Ø13mm 2 5 m 9 5044700009 Nickel DC Vermiculita Lateral 340x340x60 mm 2 10 5044700010 Nickel 700 DC Vermiculita Base lateral 210x149x30 mm 4 5044800007 Nickel 800 DC Vermiculita Base later...

Страница 23: ...CERTIFICATE OF COMPLIANCE 22 7 CERTIFICATE OF COMPLIANCE ...

Страница 24: ...CERTIFICATE OF COMPLIANCE 23 7 ...

Страница 25: ...CERTIFICATE OF COMPLIANCE 24 7 ...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea 5A 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: