ADDITIONAL FUNCTION 

CONTROLS

DISABLING BUTTON SOUNDS  

You can turn the button sounds on 
and off. To toggle the sounds on/
off, press and hold the 

. button 

longer than 2 seconds while the 
breast pump is started. 

Attention! It is only possible to disable 
the short button press sounds.  
The sounds of the long press cannot  
be disabled. 

SWITCHING BETWEEN 

EXPRESSION MODES 

Pressing and holding a 

 

button (for longer than 2 sec) 
during the “Expression” phase 
results in cyclical mode changes: 
“Physiological”; “Classic”, “Gentle”. 
Green flashing light indicated 
Physiological mode

Blue flashing light indicate 
Classic mode 

White flashing light indicate 
Gentle mode 

SAVING THE SETTINGS 

You can save your individual 
pumping settings on the device. 
Press and hold 

 and 

 buttons 

longer than 2 seconds when 
breast pump is started until you 
hear a long signal. When the 
breast pump is turned on next 
time, it will automatically start 
performing in the chosen mode 
(given that the breast pump was 
disconnected from the power 
source and was in the snooze 
mode). 

RESET THE SETTINGS 

Press and hold 

 and 

buttons longer than 2 seconds 
when breast pump is stopped. 

16

Содержание Smart

Страница 1: ...USER MANUAL LACTEA Smart LACTEA Smart Lite LACTEA Smart Plus LACTEA Smart Pro www lactea ru...

Страница 2: ...Breastpumps 4 Product description and controls 8 Assembling the pump 11 Cleaning and sanitizing 12 Operating the pump 14 Function controls and LED signal description 17 Troubleshooting 18 Technical da...

Страница 3: ...ngorgement Storing expressed breast milk Excess lactation Inadequate milk supply Flat or retracted nipples Temporary separation of the mother from the baby Certain maternal medical conditions The moth...

Страница 4: ...n phase fig 1 a fast paced rhythm about 120 cycles per minute which stimulates the letdown Next comes the expression phase a slower rhythm about 60 cycles per minute that ensures a gentle and effectiv...

Страница 5: ...Helps express more milk in the first minutes of pumping Applies a little more vacuum This mechanism is used in conventional clinical professional breast pumps 3 Gentle mode fig 4 Perfect for special o...

Страница 6: ...ACTEA Smart gives you a chance to choose just the perfect mode for you Try all three of them and see which one is the right fit Figure 3 Classic mode Figure 2 Physiological mode Figure 4 Gentle mode 6...

Страница 7: ...s expression from both breasts Double pumping allows you to save time while simultaneously increasing milk production it stimulates additional letdown expresses more milk and increases the nutritional...

Страница 8: ...UCT DESCRIPTION AND CONTROLS Power adaptor inlet Membrane lid Tubing port Power adaptor Pump motor block Breast shield size M 24 mm Bottle Bottle lid Connecting tubing Assembled milk valve Connector c...

Страница 9: ...Display Lactea Smart Plus Pro models LED indicator START STOP One touch letdown and expression mode switch Vacuum level increase decrease Vacuum outlet Membrane lid removal tag 9...

Страница 10: ...k 4 120 ml bottles 2 4 1 3 LACTEA SMART PLUS PRO DISPLAY ICONS 1 Timer duration of an expression session 2 Vacuum indicator 3 Phase mode indicator 00 00 Stimulation phase Expression phase physiologica...

Страница 11: ...BLING THE MILK VALVE FOR CLEANING AND SANITATION PURPOSES Carefully peel the membrane leaflet off the milk valve In order to assemble the valve lightly press the white membrane onto the valve until yo...

Страница 12: ...NCE DAILY 1 Completely disassemble the breast pump If the tubing was exposed to milk remove the membrane lid as well p 13 2 Place parts of the pump in boiling water for 5 minutes Make sure the parts a...

Страница 13: ...ater Next rinse it with running water Dry the lid with a cloth or let it air dry completely on a clean towel Gently wipe the silicone membrane found under the lid with a damp cloth Make sure the membr...

Страница 14: ...LACTEA power cord into the power inlet of the motor block p 8 Only use the LACTEA power adaptor BATTERY BLOCK sold separately Open the battery block lid and insert 8 AA batteries in the correct posit...

Страница 15: ...nsition to the Expression phase Use the tubing port included in the extra kit to connect the breast pump to both pumping kits Express in the same way as described for single pumping If the milk letdow...

Страница 16: ...mode changes Physiological Classic Gentle Green flashing light indicated Physiological mode Blue flashing light indicate Classic mode White flashing light indicate Gentle mode SAVING THE SETTINGS You...

Страница 17: ...ress Increase vacuum level hold 2 sec Toggle display brightness high low short press Decrease vacuum level hold 2 sec Toggle beeper on off hold 2 sec Toggle display colour balck white red blinking Gen...

Страница 18: ...to the breast pump body TROUBLESHOOTING A BREAST PUMP IS NOT FUNCTIONING The indicator is off Make sure the breast pump is plugged into the energy source The red indicator is rapidly flashing Software...

Страница 19: ...voltage Max power adaptor voltage max 0 6 A Max power consumption from 220v supply Max vacuum TECHNICAL DATA STORAGE AND TRANSPORTATION The LACTEA Smart breast pump may be stored in enclosed non heat...

Страница 20: ...ufacturer will repair this product without charge for such replacement parts or labor This warranty does not apply to any product used commercially or which has been subjected to misuse abuse or alter...

Отзывы: