Hardened Media Converter 

1

 

Quick Start Guide 

This quick start guide describes how to install and use the hardened media 
converter. T

his is the media converter of choice for harsh environments 

constrained by space. 

 

Physical Description 

The Terminal Block and Power inputs

 

 

 

y

 

DC Terminal Block Power Inputs: There are two pairs of power inputs 

can be used to power up this media converter. Redundant power 
supplies function is supported. You need to have two power inputs 
connected to run the media converter, but the FAULT LED indicator 
will light up to remind that the power redundant system functions 
abnormal in case either PWR1 or PWR2 is dead. Media Converter, 
however, continues working normally even fault LED indicator lights 
up. 

 

y

 

DC JACK Power input: 12VDC. 

 

Содержание L-EL900

Страница 1: ...rminal Block Power Inputs There are two pairs of power inputs can be used to power up this media converter Redundant power supplies function is supported You need to have two power inputs connected to run the media converter but the FAULT LED indicator will light up to remind that the power redundant system functions abnormal in case either PWR1 or PWR2 is dead Media Converter however continues wo...

Страница 2: ...t Transmit Data Input Receive Data 2 Output Transmit Data Input Receive Data 3 Input Receive Data Output Transmit Data 4 NC NC 5 NC NC 6 Input Receive Data Output Transmit Data 7 NC NC 8 NC NC 2 The 100Base FX Connections The fiber port pinouts The Tx transmit port of device I is connected to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of device II ...

Страница 3: ...Mbps 100 Mbps Off Connection at the speed of 10Mbps Steady LFPT function enabled LFP Off LFPT function disabled Steady Valid network connection established LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY LNK ACT Off Neither valid network connection established nor transmitting receiving data Steady Connection in full duplex mode FDX stands for FULL DUPLEX Flashi...

Страница 4: ...ue value 7 lb in y 40 to 75 40 to 167 operating temperature range Tested for functional operation 40 to 85 40 to 185 UL1604 Industrial Control Equipment certified Maximum Surrounding Air Temperature 74 165 y Supports Din rail Panel or Rack Mounting installation y UL1604 Class I Division 2 Classified for use in hazardous locations Applicable to versions with Terminal Block power option y This equip...

Страница 5: ...Hardened Media Converter 5 ...

Страница 6: ...olution The hardened media converter is a plug and play media converter in compact size It doesn t have any complicated software to set up This manual describes how to install and use the hardened media converter with the link fault pass through function The converter introduced here provides one channel media conversion between 10 100Base TX and 100Base FX The converter fully complies with IEEE80...

Страница 7: ...NTLING 4 PREFACE 6 TABLE OF CONTENTS 7 INTRODUCTION 8 PRODUCT OVERVIEW 8 PRODUCT FEATURES 8 PACKING LIST 9 ONE CHANNEL MEDIA CONVERTER 10 PORTS 10 PORT SETTINGS 10 DIP SWITCH 10 FRONT PANEL LEDS 11 LINK FAULT PASS THROUGH 12 INSTALLATION 13 SELECTING A SITE FOR THE EQUIPMENT 13 DIN RAIL MOUNTING 13 CONNECTING TO POWER 14 SPECIFICATIONS 17 ...

Страница 8: ...ntal requirements temperature shock and vibration for traffic control equipment y Meets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment y Support 802 3 802 3u 802 3x Auto negotiation 10 100Mbps full half duplex Auto MDI MDIX y 100Base FX Multi mode SC or ST type Single mode SC or ST type WDM Single mode SC type y One DIP switch for configuring link fault pass through fixed sp...

Страница 9: ...ing installation y UL1604 Class I Division 2 Classified for use in hazardous locations Applicable to versions with Terminal Block power option y This equipment is suitable for use in Class I Division 2 Groups A B C and D OR non hazardous locations only y WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous y WARNING EXPLOSION H...

Страница 10: ...witch settings DIP switch There are six pins on the DIP switch for port settings Refer to the table below for more details DIP switch No 0 1 1 Disable LFPT Enable LFPT LFPT link fault pass through 2 Enable auto negotiation for TX port Enable forced mode for TX port 3 TX port forced to 100Mbps TX port forced to 10Mbps 4 TX port forced to full duplex mode TX port forced to half duplex mode 5 FX port...

Страница 11: ...ED Indicators The LED indicators give you instant feedback on status of the converter LEDs State Indication Steady Power redundant system or ports function abnormally FAULT Off Power redundant system and ports function normally Steady Power on PWR stands for POWER PWR1 PWR2 Off Power off Steady Connection at the speed of 100Mbps 100 Mbps Off Connection at the speed of 10Mbps Steady LFPT function e...

Страница 12: ...K ACT and FDX COL LEDs of the TX port of the Media Converter A would be off The Media Converter B A Link Fault condition will be informed to the FX port of the Media Converter B Then a Link Fault condition will be sensed on the TX port of the Media Converter B whenever the Media Converter B detects a Link Fault condition on the FX port Thus the 100 LNK ACT and FDX COL LEDs of the Media Converter B...

Страница 13: ...should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the equipment receives adequate ventilation Do not block the ventilation holes of the equipment The power outlet should be within 1 8 meters of the product DIN Rail Mounting Fix the DIN rail attachment plate to the back panel of the media converter y...

Страница 14: ... Inputs or 12VDC DC Jack 12VDC DC Jack Step 1 Connect the supplied AC to DC power adapter to the receptacle on the topside of the media converter Step 2 Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage ...

Страница 15: ...ULT LED indicator will light up to remind that the power redundant system functions abnormal in case either PWR1 or PWR2 is dead Media Converter however continues working normally even fault LED indicator lights up Step 1 Connect the DC power cord to the plug able terminal block on the media converter and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut d...

Страница 16: ...ck are used for power failure detection It provides the normally closed output when the power source is active Use this as a dry contact application to send a signal for power failure detection Special note The relay output is normal open position when there is no power to the media converter Please do not connect any power source to this terminal to prevent the shortage to your power supply ...

Страница 17: ... FAULT LFP LED Indicators Per Port TX 3 LEDs LNK ACT FDX COL 100 FX 2 LEDs LNK ACT FDX COL Dimensions 50mm W 110mm D x 135mm H 1 97 W x 4 33 D x 5 31 H Weight 0 8Kg 1 76lbs Power DC Jack 12VDC External AC DC required Terminal Block 10 48VDC Operating Voltage Max Current Consumption 0 76A 12VDC 0 38A 24VDC 0 19A 48VDC Power Consumption 9 12W Max Operating Temperature 40 C 75 C 40 167 Tested for fun...

Страница 18: ...FI Standards EN61000 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards EN61000 4 11 Voltage Dips Standards Environmental Test Compliance IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock IEC60068 2 32 Ed Free Fall NEMA TS1 2 Environmental requirements for traffic control equipment ...