LACO Technologies UN-100V Скачать руководство пользователя страница 7

 

 

SMT-09-1009 

 

 

CAUTION:  

The unit is designed for pumping air. Do not allow corrosive gases or 
particulate material to enter the pump. Water, oil-based 
contaminants, or other liquids must be filtered out.  

 

CAUTION:  

The normal ambient temperature should not exceed 40 °C (104 °F). 
This is particularly important when the unit is installed in a confined 
space where heat may build up during operation. 

 

WARNING: 

UN-150V units are oil-less design. Never lubricate these oil-less units. 
Most components are made of aluminum and the valves are stainless 
steel. 

 

4.

 

Installation 

WARNING: 

To avoid risk of electrocution, do not use this product in an area where it 
could come in contact with water or other liquids. If exposed to the 
elements, it must be weather protected. 

 

CAUTION:  

Do not block the flow of cooling air over the unit in any way.  

 

Содержание UN-100V

Страница 1: ...UN 100V DRY PISTON PUMP OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ...ct Group UN Series Dry Piston Pumps Part Numbers UN 100V Manual Rev Number SMT 09 1009 A1 2019 LACO Technologies Inc No part of this manual may be reprinted translated or duplicated without the expressed written consent of LACO Technologies Inc ...

Страница 3: ...i TABLE OF CONTENTS 1 Alert Symbols 1 2 Specifications 1 3 Dimensions 2 4 General Information 2 5 Installation 3 6 Operation 4 7 Maintenance 5 8 Service 5 9 Troubleshooting 6 ...

Страница 4: ......

Страница 5: ...sible DANGER Severe personal injury or death will occur if hazard is ignored WARNING Severe personal injury or deal can occur if hazard is ignored CAUTION Minor injury or property damage can occur if hazard is ignored 2 Specifications Model Max vacuum Open flow Watt HP Weight 220V 50Hz 110V 60Hz UN 100V 620 mmHG 20 24 95W 1 5 3 6 Kg ...

Страница 6: ...to be used for the purpose of pumping air This pump should not be used for the pumping of fluids particles solids or any combustible substances likely to cause explosions DANGER Do not pump flammable or explosive gases or operate the unit in an atmosphere containing them ...

Страница 7: ...e unit is installed in a confined space where heat may build up during operation WARNING UN 150V units are oil less design Never lubricate these oil less units Most components are made of aluminum and the valves are stainless steel 4 Installation WARNING To avoid risk of electrocution do not use this product in an area where it could come in contact with water or other liquids If exposed to the el...

Страница 8: ...N Do not operate units above recommended pressures or vacuum duties To do so will damage unit CAUTION After use disconnect plumbing and let the unit run open for about 5 minutes in air before switching it off to purge out droplets of liquid that may have formed on the inside of the unit This prevents crystallization and or absorption of liquids WARNING This unit is thermally protected and will aut...

Страница 9: ... life 7 Service Unit Disassembly WARNING You must disconnect the unit from electrical power before servicing it Failure to do so can result in severe personal injury or death Vent all air lines to the pump to remove pressure WARNING You must vent all air lines to the unit to remove pressure before servicing the pump Failure to do so can result in severe personal injury NOTE LACO Technologies will ...

Страница 10: ...Excessive Noise Overheating Won t Start Dirty filter x x Dirty muffler x x x x Dirty valves x Damaged valves x x x Worn or damaged cup x x x Improper cylinder shimming x x x x x x Leaky hose x x Plugged vacuum or pressure line x x x x x Low voltage x x x x Leaky relief valve x x ...