background image

       LACAVA 

5

WAL L

Level 1

(most soap)

Level 2

Level 3

Level 4

(least soap)

 

Prime button

soap quantity 

adjustment access

wall

2.  Fill the soap bottle with liquid soap (make sure soap 

viscosity is within recommended range).

3.  Install the soap bottle into the mount/pump.  Then 

press and hold the Prime button until soap exits the 

spout.

4.  Place hands under spout and test the dispenser’s 

operation.

Adjust Quantity Dispensed

1.  Remove the rubber plug in order to acces the 

adjustment switches.

2.  Remove the material covering the switches so 

they can be moved.

3.  Move the switches to the desired level of soap 

quantity.

4.  Push the rubber plug back into the access hole.

rubber plug

Installation Instructions/Instrucciones de Instalación

1.  With all components mounted plug in the electricity 

sources and use the QUICK CONNECT to link the soap 

line.  Press the end of the QUICK CONNECT while sliding 

the line in until it seats.

IMPORTANT:  

DO NOT ATTEMPT TO TIGHTEN OR LOOSEN 

FITTING AT PUMP (FACTORY INSTALLED AND SEALED).

Quick

Connect

press and hold down

to slide hose in or out

Warnings:

-Do not install the soap dispenser facing a mirror-like surfaces or other electronic systems operated by 

 an infra-red sensor 

-Space for installation so that the user hands should not interfere with the soap dispenser sensor detection 

 area while operating a nearby faucet or other objects

-The soap bottle and control box must be accessible after installation  

Содержание EX02A

Страница 1: ...nstalación incorrecta Es la responsabilidad del propietario garantizar que este aparato cumpla con todos los códigos de plomería locales Por favor consulte nuestros Términos y Condiciones que se encuentran en este folleto para información adicional Para obtener asistencia técnica por favor contacte a 773 637 9600 Table of Contents Contenido Page 2 Product Specifications Especificaciones de Product...

Страница 2: ...e rounded up to the nearest 1 16 4 3 4 120 1 1 2 40 1 1 8 28 MIN ABOUT 13 3 4 350mm FLOOR POWER ADAPTER 58 long cord 1 3 4 3 1 2 45 90 Suggested 19 3 4 25 1 2 500 650 sensor Distance between spout and basin surface 10 250mm 1 1 2 40 Ø7 8 22 Ø1 1 4 32 2 1 2 65 4 1 2 115 3 3 4 95 10 255 5 125 5 1 2 140 6 1 4 160 OPTIONAL SMALL BOTTLE EXBTS 2 3 4 70 5 1 2 140 4 100 Ø 4 100 4 5 8 115 3 1 2 90 ...

Страница 3: ...lease reference this sheet and the corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes AC ADAPTER BATTERY BOX SOAP BOTTLE PUMP FIXTURE INFRARED SENSOR 1 2 3 4 5 QUICK CONNECT ...

Страница 4: ... Liquid capacity Temperature Default sensing distance 4 10cm Liquid soap viscosity 1000 3500 cPs AC 120V DC 6V 0 5 gal 1 9L Room temperature Soap volume discharge 0 07 oz 2mL level 4 levels Installation Diagram Technical Specifications Mount and install components according to the diagram min 4 100mm min 10 250mm ...

Страница 5: ...he rubber plug back into the access hole rubber plug Installation Instructions Instrucciones de Instalación 1 With all components mounted plug in the electricity sources and use the QUICK CONNECT to link the soap line Press the end of the QUICK CONNECT while sliding the line in until it seats IMPORTANT DO NOT ATTEMPT TO TIGHTEN OR LOOSEN FITTING AT PUMP FACTORY INSTALLED AND SEALED Quick Connect p...

Страница 6: ...warm water to clear them of the crystallized soap Soap residues on stainless steel and other metal finishes should be removed immediately When not removed properly cleaning soaps containing tensides can lead to corrosion of those metals Pump runs but no soap is coming from the spout Confirm soap in bottle Visually inspect the tip of the spout for blockage 1 Debris or hardened soap may be blocking ...

Страница 7: ...Asegúrese de limpiar cualquier exceso de productor de limpieza con una esponja o un trapo húmedo y luego enjuague con agua Seque la superficie con un paño suave hasta que se seque después de cada uso Nunca use materiales abrasivos o productos de limpieza que contienen amoníaco lejía o ácido ya que pueden causar daños a la superficie acabada Nos gustaría darle las gracias por su compra y estamos se...

Страница 8: ...AVA LLC proporciona una Garantía Limitada de por Vida en sus grifos Esto garantiza que cualquier grifo instalado en una aplicación residencial no presentara defectos en el material o de fabricación mientras que el consumidor original posea su casa Cualquier producto instalado en una aplicación comercial está cubierto bajo garantía por un año LACAVA garantiza que todos los otros productos no presen...

Страница 9: ...ther it was our error If we verify it was our mistake we will promptly ship the missing item s to the purchaser by standard ground at our cost RETURN POLICIES If the product is not satisfactory for any reason different from defects it can be returned to LACAVA LLC up to 30 days from the shipping date after obtaining a Return Goods Authorization RGA valid for 60 days If the product is not returned ...

Страница 10: ...gente chofer de la compañía cualquier alteración visible en el empaque En el caso que falten artículos también hay que informar a LACAVA y enviar todos los documentos relacionados con un plazo de 24 horas a partir de la fecha de entrega Vamos a abrir una investigación interna y verificar el recuento de inventario para determinar si fue un error de nuestra parte Si nos damos cuenta que fue nuestro ...

Отзывы: