INSTALLER
’S MANUAL
SAULIEU – SAVIGNY - CITEAUX
Page 15 of 47 – US –
Adjustment of reduced flowrate of surface burners (Figure 23):
After connection or change of gas, it is
crucial
to modify this
adjustment.
- Remove the control knob. Light the burner, adjust to
minimum setting, then use a small screwdriver to set the
adjusting screw
J
.
Note:
Flame is reduced to ¼ of its size in the minimum
setting, the burner must remain lit when changing from
maximum setting to minimum setting.
Refitting the cooking surface:
When refitting the cooking surface, it is vital to tighten
fastening screws (figures 13, 14 and 15). Failure to do so can
cause distortion of the cooking surface.
OVEN BURNERS:
Dismounting oven burner
Remove the oven baseplate (Fig.18).
CAUTION: when refitting place the base underneath the groove on the fascia (fig.19).
Unscrew the screw K holding the burner (Fig.20).
Remove the tray.
Unscrew the screw L (Fig.21).
Push the burner to the bottom of the oven and lift to remove it.
Fig. 19
Fig. 18
Fig. 20
K
Fig. 21
L
J
Fig. 23
Содержание SAULIEU
Страница 2: ...Page 2 of 47 US...
Страница 8: ...Page 8 of 47 US...
Страница 10: ...Page 10 of 47 US...
Страница 19: ...INSTALLER S MANUAL SAULIEU SAVIGNY CITEAUX Page 19 of 47 US S R Figure 36 Figure 37 Figure 38...
Страница 29: ...Page 29 of 47 US...
Страница 31: ...Page 31 of 47 US...