Page 9 of 17 – US –
Fig. 23
P
ELECTRICAL
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this requirement or incorrect grounding.
Before connection, check that the
:
Mains voltage is compatible with the appliance’s rated voltage and thermal output.
A power cord has been installed by the importer /
distributer. DO NOT remove this cord.
Connection:
-
Use a 4-wire cord rated for 30A (NEMA 14-30P) or 50A (NEMA 14-50P)
120/240 VAC, type SRD, SRDT, S, SO or ST.
-
Where local Codes do not permit grounding through neutral, use a 4-wire power
supply cord or “pigtail” kit. Cord must be agency approved for use with household ranges.
-
Remove access door
O, P
(Figure.22 & 23).
-
Connect to terminal block in accordance with figure 24.
-
Secure the cable by means of cable clamp
(not provided), item
Q
(Figure 25).
-
Refit access door
Power Specifications for Rully Ranges
RULLY
Voltage (V) Amperage (A) Wattage (W)
ULG732E
120 / 240
24.2
5802
ULG742E
120 / 240
24.2
5802
ULG732CT
120 / 240
23.2
5552
ULG742CT
120 / 240
23.2
5552
ULCF732E
120 / 240
24.2
5802
ULCF732CT 120 / 240
23.2
5552
THE APPLIANCE WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE
WITH THE LOCAL CODES OR The National Electrical
Code, ANSI/NFPA 70-1996 or latest edition.
ALL WORK ON OR REPAIR OF AN APPLIANCE
MUST BE CARRIED OUT BY A QUALIFIED
INSTALLER.