Cabinet preparation
:
A
B
C
D
E
F
G
H
I
J
K
mm 762-914 330
457
914
107
273
807
846
51
705
660
’’
30-36
13
18
36
4
11
32
34
2
27¾
26
Fig. 10
B
A
D
G
C
F
I
I
H
K
E
J
Gas connection
on range
Electrical connection
on range
Place electric and gas
stub-out in this area
The range is a free standing unit. If the unit is to be placed next to cabinets, the clearances shown in Figure 10
are required.
The range cooktop surface must be no lower than the adjacent base cabinet countertop surface.
Min clearances to combustibles:
0’’ (0 mm) from rear (with spacer installed).
0’’ (0 mm) from sides below 36’’ (914 mm) height.
2’’ (51 mm) from sides above 36’’ (914 mm) height.
Cabinets 13’’ (330 mm) deep may be installed above the range at least 30’’ above the plane of the cooking
surface.
Use range only with factory supplied legs.
Page 9 of 38 – US –