INSTALLER’S MANUAL
①
②
①
②
INSTALLATION/ POSITIONING
◊
Use of the back in fill panel :
This feature is particularly recommended for built-in ovens as it ensures a 50 mm gap between the
appliance and the wall. It also increases the depth of the hob to 722,5 mm.
Product code : DS 1000.
A shut-off valve must be install and accessible close to the appliance in order to isolate it from the
gas applicable or to facilitate cutting the gas supply
:
Please ensure that installation complies with
local applicable regulations and standards
-
Natural gas supply :
Mandatory to install an Automatic Shut-off Valve (since 1st July 1997 in France)
-
LPG supply (butane, propane) :
Propane : Class 1 Safety Expansion Valve.
Butane :
Butane safety expansion valve fitted to the cylinder (connected to the range by a LPG
approved hose, maximum length 2 metres).
We recommend the front edge of the hob be positioned 50 mm further forward than the adjacent
fittings
.
(see below).
If the adjacent parts contain heat-sensitive materials, ensure there is a 50-mm gap between the
side of the oven and the parts in question.
Ensure that the materials adjacent to the lateral panels of the oven are not
flammable.
Back in fill panel
Cluny induction - Ft 151a - GB - Rév 05 - Modifié le : 07/10/2013 8/31