In case of use with a gas other than that for which the appliance was initially set up, it is
crucial
to replace the orifices
and modify the adjustments as defined below.
TOP BURNERS
Orifice
Lift the air ring
E
. Replace the injectors
F
in accordance with
Table 3 and Figure 13 (Ø in 1/100 mm).
The side burner bodies are kept in place by a transversal bar
(
H
, fig. 15). In order to take them out, unscrew screws
I
(fig.
16) then
G
(fig. 14).
Note
:
When one or more nozzles are changed, the sealing ring
should be changed as well (see gas circuit diagram).
Adjustment of primary air
Put body & cap back on their respective burners, set air ring
E
by
sliding it from bottom to top (fig. 13, Table 4).
Note :
Normal flames are bluish green except for natural gas flames
which are violet.
Table 3
Top burners
5000 11000 15000 18000
GAS
Pressure
Natural gas
6" WC
0.90
1.30
1.45
1.70
L.P. propane
10" WC 0.65
0.90
1.05
1.20
Clé de 12
Wrench 12 (
15
/
32
)
Fig. 13
F
E
Clé de 3
Wrench 3 (
1
/
8
)
Fig. 14
G
I
Fig. 16
Clé de 7
Wrench 12 (
15
/
32
)
H
Fig. 15
Table 4
Top burners
5000
11000 15000 18000
GAS
Pressure
Opening / inches
Natural gas
6" WC
2,5 /
1
/
8
2,5 /
1
/
8
max
7 /
1
/
4
L.P. propane
10" WC 3,5 /
1
/
8
max
max