![background image](http://html1.mh-extra.com/html/lacanche/bussy/bussy_manual_3226250013.webp)
I N STALLER’S M AN UAL
Table 2
Burners
SF
F
I
GAS
Pressure
Natural gas
6» WC
0.90 1.30 1.45
L.P. propane
10» WC
0.65 0.90 1.05
CHANGE OF GAS
Changing the gas type of the hob/ Setting gas burner hob :
Hob injector:
►
L
ift the air ring
A
/ figure
4
.
►
R
eplace the injectors
B
in accordance with table
2
and figure
4
( Ø in 1/100 mm).
I
f necessary, the mixer tubes of the lateral burners maintained by a cross-bar
C
/ figure
5
, may
be release
d.
T
o release the tubes loosen screws
D
/ figure
2
and then screw
E
/ figure
6
.
N.B.
When replacing injector(s), also replace the sealing washer (see paragraph “Gas Line”).
L
acanche ranges are supplied with the gas itting requested when the order is placed. The settings
must be ine-tuned when the range is installed.
IMPORTANT : Close the mains gas valve before carrying out any works.
IMPORTANT
In case of use with a gas other than that for which the appliance was initially set up, it is
crucial to replace the injectors and modify the adjustments as deined below.
wrench, 12
F
4
6
5
B
C
A
E
D
7
Notice provisoire Beaune - Bussy UL - FT164h - Date : 16/10/12
13/42
Содержание BUSSY
Страница 6: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 6 42...
Страница 8: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 8 42...
Страница 30: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 30 42...
Страница 34: ...Notice provisoire Beaune Bussy UL FT164h Date 16 10 12 34 42...