16 | MRP Mobile Rotating Pulverizer Operation & Maintenance Manual
EVERY 40 HOURS
Inspect Hardware
_______
Check the play between the pins and bushings on the attachment bracket. If the play is greater than 0.6 mm,
replace the bushings and pins.
Lubrication
_______
Grease the pinion and teeth of the rotating head (See “Lubrication” on page 17).
Inspected By: _______________________________________________ Date:_____________________
EVERY 6 MONTHS
_______
Inspect the gaskets on the rotation bearing.
Inspected By: _______________________________________________ Date:_____________________
EVERY 12 MONTHS
_______
Visually inspect the cylinder. Ensure there is no oil leakage.
Inspected By: _______________________________________________ Date:_____________________