LaboGene CoolSafe Basic 55-4 Скачать руководство пользователя страница 6

Instruction manual for CoolSafe 

 

 

06012017QA01 

Item No. 700749 

CopyRight © 2017

 

Page 

4

 of 

20

 

 

Introduction 

This manual covers the CoolSafe models Basic and Pro. The models are: 
 
CoolSafe Basic: 55-4, 55-9 and 110-4 
 
CoolSafe Pro: 55-4, 55-9, 55-15, 95-15, 100-9 and 110-4. 
 
CoolSafe 4-15 l is an outstanding and versatile range  of  advanced bench-top freeze dryers. They 
are  the  product  of  more  than  40  years’  experience  and  expertise,  and  are  the  ideal  choice  for 
research, process development and small-scale production.  
 
All sizes come with a choice of condenser temperatures and a wide range of high-quality chambers 
and  accessories.  All  models  offer  both  simplicity  of  operation  and  the  highest  performance 
character

istics to meet the demands of today’s research and development laboratories. 

 

 

Lowest condenser temperatures of -55°C, -95°C, -100°C or -110°C. 
 

 

Seamless  stainless  steel  condenser  with  external  cooling  coils,  heavily  insulated  to 
conserve energy and increase performance Easy removal of water via drain valve.  
 

 

Easy draining with built-in valve, allowing removal of water after a completed freeze-drying 
session. 

 

 

Very simple to operate.  

 

 

Wide choice of manifolds, chambers and accessories to suit your sample requirements. 

  

 

Available with 4-litre condenser capacity and temperature options of -55°C or -110°C and 
condenser ice capacity of 2.5 kg/24 hours - max. 3 kg in total. 

 

 

Available with 9-litre condenser capacity and temperature options of -55°C or -100°C and 
condenser ice capacity of 4 kg/24 hours - max. 7 kg in total. 

 

 

Available with 15-litre condenser capacity and temperature options of -55°C or -95°C and 
condenser ice capacity of 6 kg/24 hours - max. 10 kg in total. 

 
If  you  are  not  familiar  with  the  freeze-

drying process, please read the section “The freeze-drying 

process”, which outlines the freeze-drying process. 

Safety precautions 

2.1 

General information 

Please read this entire manual to fully understand the safe and effective use of this product. Should 
you have any comments about this manual we will be pleased to receive them. 
 

 

Note

 

If this equipment is used in a manner not specified by the manufacturer, the 
protection provided by the equipment may be impaired. 

2.2 

Safety 

All CoolSafe models are electrically protected with an over current circuit breaker.  
 

Содержание CoolSafe Basic 55-4

Страница 1: ...SOLUTIONS TECHNIQUES pour laboratoires industries...

Страница 2: ...Nos comp tences et services associ s Installation Maintenance R paration Distribution Location M trologie Qualification Conseil Qualit tude Formation Une quipe de sp cialistes...

Страница 3: ...06012017QA01 Item No 700749 CopyRight 2017 Page 1 of 20 INSTRUCTION MANUAL CoolSafe Basic Pro Size 4 9 15 Temperature 55 95 100 110...

Страница 4: ...ger of a serious accident or lethal injury Caution Used in case of danger of medium or minor injuries or physical damage This document is the original instruction manual in accordance with the current...

Страница 5: ...lve 8 5 Operation 8 5 1 User interface 9 5 2 Error situations status and error codes 9 5 2 1 Status codes 9 5 2 2 Error codes 9 5 3 Preparations 10 5 4 Freeze drying Fejl Bogm rke er ikke defineret 5...

Страница 6: ...t in valve allowing removal of water after a completed freeze drying session Very simple to operate Wide choice of manifolds chambers and accessories to suit your sample requirements Available with 4...

Страница 7: ...multaneously 3 Installation 3 1 Installation of CoolSafe Make sure that the mains supply is according to the specifications on the type label placed on the rear panel It is important that free air cir...

Страница 8: ...Basic or Pro is a basic unit and must be equipped with the necessary accessories to run a specific freeze drying process Select from the wide range of accessories listed in the accessories section Ma...

Страница 9: ...N OFF switch The CoolSafe is designed to be plugged into a standard wall socket with build in earth and minimum 10 A fuse The CoolSafe is delivered with a country specific power cable which is connect...

Страница 10: ...valve A hose may be attached to the nozzle to minimize spillage Remember to close the drain valve after use 5 Operation The freeze drying process is a balance between the heat absorbed by the sample t...

Страница 11: ...the ice condenser is cooling down Change to OK state when the ice condenser reaches this temperature for the first time Ice condenser not ready 40 C 70 C 70 C Wait If the temperature in the ice conden...

Страница 12: ...r should have only a maximum 10 mm oil level preferably it should be empty Switch on the CoolSafe and the vacuum pump The lowest temperature should be achieved within 60 minutes The vacuum pump should...

Страница 13: ...position B The AWO Indicator should always be green prior to connecting the next flask The freeze drying process is now in progress Freeze drying Air flow B 4 To stop the freeze drying process turn th...

Страница 14: ...rying process Close the vacuum valve and let the pump run for a minimum of 45 minutes after the freeze drying has ended This is to avoid any possible condenses remaining in the pump oil If the freeze...

Страница 15: ...ator chamber it must be cleaned up immediately Cleaning of acrylic components use only mild detergents solutions NEVER solvents Wipe stainless steel surfaces with alcohol and then dry do not use abras...

Страница 16: ...er that interfaces with the top stainless steel part of the CoolSafe This can be done by squirting or brushing some frothy soap solution all around if there is a leak this will be sucked in towards th...

Страница 17: ...ave an impact on the structure of the material being dried Freeze drying is achieved using equipment that controls temperature and pressure in the environment of the product and is a 3 step process In...

Страница 18: ...50 60 Power consumption W 500 Insulation mm 90 Condenser capacity kg 3 Condenser capacity per 24 hours kg 2 5 Total volume of Condenser L 4 Weight net kg 40 Cabinet dimensions DxWxH mm 500x400x520 Ca...

Страница 19: ...al Polyester coated steel Condenser material Stainless steel AISI 316 Cooling media R 507 Vacuum Valve Electrical Drain tap Yes 8 2 CoolSafe 95 C and 100 C CoolSafe Basic or Pro 95 15 Unit Item Digita...

Страница 20: ...ster coated steel Condenser material Stainless steel AISI 316 Cooling media R 507 R170 Vacuum Valve Electrical Drain tap Yes 8 3 CoolSafe 110 C CoolSafe Basic or Pro 1 1 0 4 Unit Item Digital read out...

Страница 21: ...Instruction manual for CoolSafe 06012017QA01 Item No 700749 CopyRight 2017 Page 19 of 20 10 Declaration of conformity...

Страница 22: ...46 13 0 1 986 22 2 0 835 44 0 0 081173 4 0 4 371 13 2 1 951 22 4 0 819 46 0 0 064112 4 2 4 298 13 4 1 915 22 6 0 803 48 0 0 050383 4 4 4 226 13 6 1 880 22 8 0 789 50 0 0 039387 4 6 4 154 13 8 1 847 23...

Страница 23: ...Gardez un il sur laboandco com laboandco com LABO AND CO 50 avenue de Grosbois 94440 Marolles en Brie Tel 01 45 98 74 80 Fax 01 45 98 77 23 contact laboandco com...